HDSL4 for General Distribution Installation and Maintenance Practice
Control Port Operation
61223HDSL4L2-5C
29
View Detailed Status
The View Detailed Status selection from the Span Status Screen menu (
) displays
the HDSL4 status for each receiver point.
Figure 21. Detailed Status Screen
View Auto In Service Status
The Auto In Service Status Screen (
) provides the status of the Auto In Service
feature. This option is only available the Total Access 3000 H4TU-C.
Figure 22. Auto In Service Screen
Circuit ID:HNTSVLALHDSL4 03/09/05 09:29:45
Press ESC to return to previous menu
Detailed Status Screen
LOOP 1 LOOP 2
MARGIN ATTEN MARGIN ATTEN
Interface (CUR/MIN/MAX) (CUR/MAX) (CUR/MIN/MAX) (CUR/MAX)
--------- ------------- --------- ------------- ---------
H4TUC 17/00/17 00/00 17/00/17 00/00
H4R1 NETW 17/00/17 00/00 17/13/17 00/00
H4R1 CUST 17/17/17 00/00 17/00/17 00/00
H4R2 NETW 17/00/17 00/00 17/13/17 00/00
H4R2 CUST 17/17/17 00/00 17/00/17 00/00
H4TUR 17/00/17 00/00 17/00/17 00/00
1. Reset Min/Max
2. View Performance History
Selection:
Shelf: 1 Slot: 15 Total Access System 03/09/05 10:59
Unacknowledged Alarms: CRITICAL MAJOR INFO
Circuit ID:
Auto In Service Status Screen
Current Auto In Service State = Out-of-Service Maintenance
Auto In Service Status = Currently in Startup Period
Auto In Service Criteria = DSL Loop Sync (T1 alarms ignored)
NOTE: The external alarms provisioning option determines
whether T1 alarms are an auto in service criterion.
Enabling external alarms sets T1 alarms as a criterion.
Criteria Status
--------------- ------
DSL Loop Sync LOS
---Startup Period Timer---
4 hrs 0 mins
--------------------------------------------------------------------------------
1. View Alarm History
Selection: