Control Port Operation
HDSL4 for General Distribution Installation and Maintenance Practice
48
61223HDSL4L2-5C
View Splice Results
Select the View Splice Results screen (
) to display test results for each transceiver.
The results, in the Splice Detection Results column, are as follows:
• NTF - No Trouble is Found on the circuit.
• LOS - Loss of Synchronization (remote unit has not been detected).
• Number - Reported if an anomaly has been detected a number of times that exceeds the
detection count threshold of eight. The number shown in this column represents the
number of feet from the transceiver (Reference Point) to that anomaly.
In this example, a detection has occurred approximately 650 feet from Loop 2 of the H4TU-C
module.
The (B) Back command access to the previous 14 days Splice Detection Results.
Figure 44. View Splice Results Screen
Circuit ID:HTSVALHDSL4 03/09/05 07:32:04
Press ESC to return to previous menu
* Note: Chronic Circuit Results are only valid after all other circuit *
* qualification tests have been performed and failed to show a trouble !! *
Splice Detector Version 1 Result Definitions:
---------------------------------------------
NTF - No Trouble Found yet.
LOS - Unit not in sync.
Number - Distance from Reference point (in ft.) of suspect splice.
Reference Splice Detection Results Version Result Shown
Point Loop 1 Loop 2 Number for date
--------- ---------- ---------- ------- MM/DD/YY
H4TUC NTF 650 01 --------
H4TUR NTF NTF 01 03/09/05
H4RU1 NET NTF NTF 01
H4RU1 CST NTF NTF 01 (B)Back