HDSL4 for General Distribution Installation and Maintenance Practice
Installation Guidelines
61223HDSL4L2-5C
5
INSTALLATION GUIDELINES
After unpacking an HDSL4 module, inspect it for damage. If damage has occurred, file a claim
with the carrier, then contact ADTRAN Customer Service. For more information, refer to
. If possible, keep the original shipping container for returning the
module for repair or for verification of shipping damage.
CAUTION
Electronic modules can be damaged by Electro-Static Discharge
(ESD). When handling modules, wear an antistatic discharge wrist
strap to prevent damage to electronic components. Place modules
in antistatic packing material when transporting or storing. When
working on modules, always place them on an approved antistatic
mat that is electrically grounded.
ADTRAN HDSL4 modules plug directly into the enclosure. Installation wiring is not required.
WARNING
Up to –200 VDC may be present on telecommunications wiring.
The DSX-1 interface is intended for connection to intra-building
wiring only. Ensure chassis ground is properly connected.
NOTE
These products are intended for installation in
restricted access
locations
only.
Powering Options
H4TU-C
The H4TU-C is default enabled for span powering mode. The H4TU-C has the ability to power
one, two, or three elements and can be set to have span power disabled when the H4TU-R is
locally powered and no H4Rs are on the circuit.
C A U T I O N
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.