Control Port Operation
HDSL4 for General Distribution Installation and Maintenance Practice
26
61223HDSL4L2-5C
Provisioning Menu (Total Access 3000 H4TU-C)
The Provisioning menu for the Total Access 3000 H4TU-C occupies two screens, which are
shown in
.
• To view screen 2, press
N,
and press
E
NTER
.
• To return to screen 1, press
P
, and press
E
NTER
.
Figure 17. Total Access 3000 H4TU-C Provisioning Screen 1
Figure 18. Total Access 3000 H4TU-C Provisioning Screen 2
To re-deploy this unit, press
D
. This restores the factory default settings to those shown in
.
Shelf: 1 Slot: 14 Total Access System 03/09/05 10:59
Unacknowledged Alarms: INFO
Circuit ID:
Provisioning
1. DSX-1 Line Buildout = 0-133 Feet
2. DSX-1/DS1 Line Code = B8ZS
3. DSX-1/DS1 Framing = ESF
4. Forced Frame Conversion = Disabled
5. Smartjack Loopback = Enabled
6. Loopback Timeout = 120 Min
7. Latching Loopback Mode = T1 (Disabled)
8. DS1 TX Level = 0 dB
9. Span Power = Enabled
10. Customer Loss Indicator = AIS / CI
11. PRM Setting = AUTO
12. Loop Atten Alarm Thres = 34dB
13. SNR Margin Alarm Thres = 04dB
14. Remote Provisioning = Enabled
15. Service State = OOS Maintenance
16. Network Source = DSX
N. Next Page
Selection:
Shelf: 1 Slot: 14 Total Access System 03/09/05 10:59
Unacknowledged Alarms: INFO
Circuit ID:
Provisioning
17. External Alarms = Disabled
18. Auto In Service = Enabled
19. Auto IS Startup Period = 4 hours
20. Auto IS Off Period = 8 hours
D. Restore Factory Defaults