63
All the other settings under ‘Config’ menu are similar to ‘Mode of EDM’. refer
to the explanation above.
Note:
the ‘NEZ’ or’ ENZ’ mode of coordinates are in relation to the order of
the exported coordinate only.
9.6.
Calibrate &config
The menu is as show below:
9.6.1.
Adjusting index error (I.E)
To adjust index error, the system will first ask you to ‘Aim at a target F1’. You
may press ‘ENT’ to confirm after aiming and the instrument will measure its
horizontal angle automatically. The HA will be displayed for one second and the
system will ask you to ‘Aim at a target F2’. Following the same steps, the instrument
will then calculate the index error and display it.
Now press ‘ENT’ to save the index error (calibration done), otherwise press
‘ESC’ to quit (previous I.E remains).
9.6.2.
Calibrate TILT
When calibrating tilt, make sure that the tilt is off and the index error is little.
First, place the instrument as picture shown below with collimator facing up.
This will help screw C to adjust the inclination of the instrument.
Enter the dialog of tilt calibration program:
VA:
90
°
00
′
00
″
Comp.
X=125
F1 Up 3
′
Summary of Contents for Total Station ATS-120 Series