56
operate the instrument normally.
Note:
Never delete or alter the two ‘.sys’ files in the instrument. Do not copy
senseless files that have nothing to do with the Total Station measurements.
9.4.
Programs
9.4.1.
Remote height (REM)
REM is adequate for measuring the height of target when the prism cannot be
placed at the target point. Under ‘REM’ mode, you can place the prism on any point
along the plumb line of the target point to obtain the height of target.
There are two modes for ‘REM’ measurement: ‘with TH’ and ‘without TH’.
You can select ‘with TH’ mode when you need the altitude from the ground to the
target or ‘without TH’ when you need the altitude from any reference point to the
target.
With TH:
1.
Enter the height of instrument and the height of target firstly.
2.
Press ‘ENT’ to enter the interface of ‘REM-Prism’
3.
4.
Aim at the prism and press the soft key ‘Meas’ to obtain the horizontal
distance of the target from the instrument. Then, press the soft key ‘Enter’
to enter the interface of ‘REM-Ground to target’
Summary of Contents for Total Station ATS-120 Series