![ADC Soneplex Soneplex Fiber Hub Cabinet SPX-CABFIN04 User Manual Download Page 67](http://html1.mh-extra.com/html/adc/soneplex-soneplex-fiber-hub-cabinet-spx-cabfin04/soneplex-soneplex-fiber-hub-cabinet-spx-cabfin04_user-manual_2848187067.webp)
LTPS-UM-8007-01, Issue 1
Appendix A - Maintenance
SPX-CABFIN01, SPX-CABFIN04
November 9, 2001
55
A
PPENDIX
A - M
AINTENANCE
B
ATTERY
M
AINTENANCE
1
Ensure that the batteries and drawers are clean and dry.
2
Ensure that threaded connections are tight. In high discharge rate applications or areas subject to high
vibration, periodically check tightness for a torque value of 65-70 in-lb (735-790 [N-cm]) maximum.
3
Remove each battery protective cover and inspect the battery terminals.
4
Ensure that the terminals are clean and the connections are tight.
5
If necessary, clean and tighten the terminals in accordance with local practices, using approved cleaning
solutions.
6
Reapply No-Ox compound, and replace each battery protective cover.
7
The cells do not contain any free electrolyte and never require topping up. However, written records must be
kept of battery and cell voltages, so that long-term changes in battery condition may be monitored.
(Refer to the Battery Installation and Maintenance Record supplied with the batteries.)
Perform battery maintenance at the intervals prescribed by local practices.
Do not scrape or wire-brush the battery connectors.
Records must be kept to ensure warranty protection.