www.adblighting.com
Quick Start - page 30
Issue 1.0
-
Fail: action implemented in the absence
of the universe (see “Priority/DMX fail”
menu), three actions are possible:
•
"last value": the last values received to control the circuits are used
permanently as long as the universe is missing,
•
"cue" 0: the values of the universe channels are replaced by the content of cue
0 and will be played as long as the universe is missing,
•
"black": the control value of each circuit fades to zero intensity (black) in 5
seconds.
•
When the universe is present once more, a fade is launched to the intensities
given by ARTNET in a time of 5 seconds.
When the universe is present once more, a fade is launched to the intensities given by
ARTNET in a time of 5 seconds.
-
start addr.: value of the universe channel to address cabinet output 1, see "ARTNET
PATCH" menu
•
"x": 1 ≤ x ≤ 512
•
"not used": channel value = 0 or > 512
•
"- - - - -": no circuit physically present in cabinet location 1, or circuit
identification error in cabinet location 1 or operating fault.
-
Patch: see "ARTNET PATCH" menu,
•
Yes: the addressing entered in each patch at the circuits is not in ascending
order,
•
No: the addressing entered in each patch at the circuits is in ascending order,
e.g. 1, 2, 3, 4,…., 128 in the case where 32 modules are present in the
cabinet.
-
Subnet: value between 0 and 15, see "ARTNET config" menu
-
Port: value between 0 and 15, see "ARTNET config" menu
Note:
When the ARTNET entries are controlled by an ISIS rotating ADB console, all the
subnets must have the same number.
Ethernet Information
The IP address of each controller and the value of the sub-network mask are given.
Important:
the IP addresses of each controller must be different. If this is not the case, it
is imperative to address the ADB technical department.
Summary of Contents for EURODIM TWIN TECH
Page 1: ...Installation Manual V 1 2 EURODIM Twin Tech M 3213 1106 03 213 Lighting Technologies ...
Page 2: ......
Page 6: ...EURODIM TWIN TECH www adblighting com Installation manual Page 4 Version 1 2 2 DESCRIPTION ...
Page 61: ...EURODIM TWIN TECH www adblighting com Installation manual Page 59 Version 1 2 Notes ...
Page 62: ...EURODIM TWIN TECH www adblighting com Installation manual Page 60 Version 1 2 Notes ...
Page 63: ......
Page 65: ...EURODIM Twin Tech SF 3213 1106 03 213 Lighting Technologies Quick Start Guide Issue 1 0 ...
Page 66: ......
Page 83: ...www adblighting com Quick Start page 17 Issue 1 0 6 Menu Tree Structure ...
Page 98: ...www adblighting com Quick Start page 32 Issue 1 0 Personal Notes ...
Page 99: ......
Page 101: ...User Manual V 1 1 EURODIM Twin Tech M 3213 1106 53 213 Lighting Technologies ...
Page 102: ......
Page 165: ......