6.2.1.3 Replace the bottom cover and converter
Remove
1. Disassemble the light fixture.
2. From inside the housing, disconnect all cables from the LED board.
Replace
1. Place the new gasket on the new bottom cover with converter, see
.
Figure 17: Gasket
2. Connect the LED board cable(s). Note the orientation and alignment of the cables in
and
.
Note
Make sure that light fixtures with only one LED board cable is connected to the LED B-channel.
Figure 18: Converter with 1 connector
Figure 19: Converter with 2 connectors
3. Assemble the light fixture.
6.2.2 Workshop Maintenance 12" fixture
6.2.2.1 Open and close a 12" fixture
Remove
1. Place the light fixture upside down and remove the four screws for the bottom cover using an Allen key 5 mm, see
.
2. Lift up the housing and disconnect the LED board cable connector from the LED boards in the top cover, see
Note
Open the light fixture cautiously, be careful not to damage the LED-board cables.