CAUTION
Use of incorrect combination of gaskets, bolts and nuts can create severe damages to the product installation and
create multiple safety risks.
Make sure to know what base the light fixture will be installed in, in order to chose the correct gasket, bolts and nuts.
Failure to follow these cautions can result in equipment damage or aircraft FOD.
4.4 Installation and removal of the 12" light fixture
Install the light fixture in the base
1. Carefully clean all contact surfaces of the light fixture and the base.
2. Put the O-ring gasket in the gasket track on the base.
Note
Not for class 2.
3. Connect the connector(s) of the light fixture to the base supply cable(s). Check that the A- and B-side are connected to
corresponding circuit if two connectors are used.
4. Place the connector under the light fixture and install in the base.
5. For an installation on bases use a torque limiting box spanner of 16/17 mm, install and tighten the six fixing bolts to a
torque of 40 Nm (= 4 kg m) or nuts to a torque of 35 Nm (= 3.5 kg m). Torque value with regards to Eurobase 12", please
see specific base specification. For other base manufacturers, refer to their specifications.
Note
Do not use high speed for tightening, the recommended speed is 10
‑
40 rpm.
6. After installation, make sure that each light fixture functions properly.
7. In order to bond the light fixture to ground, use the supplied screw (Torx M4x6 mm, Torque 2.5Nm) to attach the braided
ground strap to the grounding point on the light fixture. The grounding point is indicated by a grounding symbol and
located on the bottom side.
UM-0197, Rev. 1.0, 2019/11/19
17
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for RELIANCE IQ L-852G(L)
Page 2: ......
Page 12: ...RELIANCE Inset Light Safety 6 Copyright ADB Safegate All Rights Reserved ...
Page 14: ...RELIANCE Inset Light About this Manual 8 Copyright ADB Safegate All Rights Reserved ...
Page 20: ...RELIANCE Inset Light Introduction 14 Copyright ADB Safegate All Rights Reserved ...
Page 50: ...RELIANCE Inset Light Spare parts 44 Copyright ADB Safegate All Rights Reserved ...
Page 51: ...UM 0197 Rev 1 0 2019 11 19 45 Copyright ADB Safegate All Rights Reserved ...
Page 52: ......