The minimum thread engagement into top flange of base is 0.5".
•
As required to ma0/ through -1/16" below grade FAA installation tolerance, a maximum of three spacer rings may
be stacked together.
1. Carefully clean all contact surfaces of the light fixture and the base.
2. Put the O-ring gasket in the gasket track on the base.
3. Connect the connector(s) of the light fixture to the base supply cable(s). Check that the A- and B-side are connected to
corresponding circuit if two connectors are used.
4. Place the connector under the light fixture and install on the base.
5. For an installation on bases use a torque limiting box spanner of 16/17 mm, install and tighten the two fixing bolts. For
specific torque details on different installations, see
Base O-ring and bolt selection
Note
Do not use high speed power tools for tightening, the recommended speed is 10
‑
40 rpm.
6. After installation, check that each light fixture functions properly.
7. In order to bond the light fixture to ground, use the supplied screw (Torx M4x6 mm, Torque 2.5 Nm) to attach the braided
ground strap to the grounding point on the light fixture. The grounding point is indicated by a grounding symbol and
located on the bottom side.
Remove the fitting from the base
CAUTION
Fall- and trip hazard! When a light fixture has been removed, the base must be fitted with a cover designed for this
purpose or with a spare light fixture.
1. Remove the light fixture from the base using two large flat blade screwdrivers.
2. Disconnect the secondary supply connector.
3. Remove and check the O-ring gasket.
Note
It is recommended to change the gasket, lock nuts or bolts each time the light fixture is removed or dismounted from
the base.
RELIANCE Inset Light
Installation
16
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for RELIANCE IQ L-852G(L)
Page 2: ......
Page 12: ...RELIANCE Inset Light Safety 6 Copyright ADB Safegate All Rights Reserved ...
Page 14: ...RELIANCE Inset Light About this Manual 8 Copyright ADB Safegate All Rights Reserved ...
Page 20: ...RELIANCE Inset Light Introduction 14 Copyright ADB Safegate All Rights Reserved ...
Page 50: ...RELIANCE Inset Light Spare parts 44 Copyright ADB Safegate All Rights Reserved ...
Page 51: ...UM 0197 Rev 1 0 2019 11 19 45 Copyright ADB Safegate All Rights Reserved ...
Page 52: ......