USER’S MANUAL V-line AdBlue
®
47xx.xxx
2
i)
Service operations and installation can be provided only by trained service persons.
Service operation must be in accordance with operation rules of the filling station.
Producer does not response for damages made by non qualified persons.
j)
Provider can start delivery after close of filling station revision and after official metrologic
inspection of
AdBlue
®
dispensers
.
k)
By delivery of the AdBlue
®
must be kept basic hygienic rules. Provider must allow to the buer to use
hand protection like as ecoplastic sloves.
l)
During operation of
AdBlue
®
dispenser
in winter time (ambient temperature lowering (T
amb
.) under
freezing point) must be permanent switch on heating function of
AdBlue
®
dispenser
and storage
container. This notice is valid even the filling station i sout of order.
PLEASE STORAGE THIS MANUAL FOR NEXT USE!
2.
USE
AdBlue
®
dispensers
of type line
V-line AdBlue
®
47xx.xxx
is designed for delivery AdBlue
®
into vehicles with
diesel engine. AdBlue
®
is reducing agent AUS 32 ISO 22241, used in vehicle catalysators powered by diesel
with catalic selective reduction for lowering of emissions NO
x
.
They have been designed for the installation at road filling stations and a fleet of vehicles, etc.
By means of a communication line the dispensers are connected to the control system of self-service
operation or serviced operation.
The dispensers are equipment with special requirements concerning safety, metrology and ecology.
ATTENTION!
AdBlue
®
dispenser V-line AdBlue
®
47xx.xxx
can be operand only with reduction agent
AUS 32 ISO 22241.
Any use for delivery of flammable fluids is not allowed !
3.
INSTRUCTIONS FOR THE SAFETY OF WORK
3.1.
Safety of the equipment design
AdBlue
®
dispenser
is designed for installation to outside conditions
Enviromental class
C (outside - stationar)
Mechanical class
M 2 - for electronic Beta Control ADPxxx
M 1 – for electronic UNIDATAZ CDC
Electromagnetical class
E 2 - for electronic Beta Control ADPxxx
E 1 – for electronic UNIDATAZ CDC
Enviroment humidity
With condensation
ATTENTION!
AdBlue
®
dispenser may not be installed to danger explosive zone 0, 1, 2 in meanings of dedicated
zones as per ČSN EN 60079-10-1!
From point of technical requirements settled for measurement units was at the AdBlue
®
dispenser
performed EU type examination (type certification) according to Annex II, Module B of the Directive
of European Parliament and the Council 2014/32/EU authorised body – Český metrologický institut,
Okružní 31, 638 00 Brno – Notified body No. 1383.
EC - Type Examination Certificate: No. TCM 141/07 – 4518
Summary of Contents for AdBlue V-line 47 Series
Page 2: ......
Page 11: ...USER S MANUAL V line AdBlue 47xx xxx 7 Figure 2 ...
Page 28: ......
Page 33: ...USER S MANUAL V line AdBlue 47xx xxx Enclosure No 5 ...