USER’S MANUAL V-line AdBlue
®
47xx.xxx
9
4.3.3
Electromagnetic(solenoid) valve
Electromagnetic valve is placed on meter output. Valve control is provided by electronic counter. Body of
the valve is nicle plated, pistons and bushes are finished from material on teflon basis.
Electromagnetic valve is supplied as option upon costumer request.
4.3.4
Delivery hose AdBlue
®
Delivery hose AdBlue
®
is finished from speciall rubber designed for AdBlue
®
. Delivery hose is placed on hose
reel and ended by delivery nozzle.
4.3.5
Delivery nozzle AdBlue
®
Speciall finishing of components delivery nozzle ELAFLEX AdBlue
®
made from materials resistent to
medium AdBlue
®
. The nozzle is equiped by automatic closing valve, function STOP system preventing tank
overfilling and by swivel.
Inside of nozzle spout is build in magnetic valve.The dispensing is possible only if the defined magnetic
zone in filling inlet of vehicle tank will open magnetic svitch in spout of delivery nozzle. By this safety
fiction is eliminated to fill different fuel tank by product AdBlue
®
. Delivery nozzle is hanged in speciall
vertical cover imide of external module of AdBlue
®
dispenser. Nozzle space is covered by front doors a in
temperature fall down is heated.
The nozzle with covering doors can be locked if the station is in off mode.
4.3.6
Connection elements
Connections of hydraulic system of container filling station is made by connecting pipes and fittings made
from speciall stainless steels and speciall ruber hose resistent to AdBlue
®
.
Baal valve G 1“
4.4.
Electronics
The dispenser control shall meet the exacting requirements of simplicity and convenience and depends on
the hanging up and lifting of the dispensing nozzle.
ADPMPD/T, ADPMPD/T-PWM, ADP1/T, ADP2/T, ADP1/L
electronic counter
of an up-to-date design with
central processor board equipped with a high efficient microprocessor. The configuration of the counter
and its modes of operation are adjusted by more than seventy parameters. The counter is provided with a
self-diagnostic system. The counter outlets control the motors, valves, signalling circuits and vapours
exhaustion. The electronic counter processes the impulses coming from the impulse sensor and transmits
them to the display, which displays the dispensed volume, its price and a price per a volume unit. In case
of power failure or voltage drop the data displayed on the LCD remain for 30minutes at least.
Counters ADPMPD/T, ADP1/T, ADP2/T, ADP1/L are standardly equipped for electronic meter calibration
(Electronic Calibration of Meters – EC)
and per request by
ATC – (Automatic Temperature
Compensation).
Electronic Calibration of Meters (EC)
enable to correct measured volume by designed declination in
operation range -5,00 % to +5,00 % of recognised meter non accurancy by step of 0,05 %.
Baal valve G 1“
Filter flange
Connecting pipe
between the
filter and meter