USER’S MANUAL V-line AdBlue
®
47xx.xxx
11
4.6.
SOPA design
On Client’s special request the dispenser in service mode can be equipped with magnetic release switch
(SOPA design). The operator of the filling station can release the dispenser for single filling operation in this
mode. After nozzle lifting the displays are reset and fuel filling is started.
After hanging up the nozzle, the dispensed volume and quantity values are permanently displayed until the
dispenser is magnetic released and the dispensing nozzle is lifted off subsequently. The red signal light
informs both the operator and the customer about the condition of the dispenser.
4.7.
Design with heating of the electronic case
On the special customer´s requirement the fuel dispenser can be delivered with heating of electronic case
by heater 250 W. For feeding of the heating is used an individual cable.
4.8.
Heating of hydraulic housing
In the closet hydraulically dispenser is built powerful fan heater with thermostat - power 950 W. Protects
interior hydraulic hose module and the module against condensation and thermal protection components of
the hydraulic system of the dispenser against crystallization and
AdBlue
®
freezes when temperatures drop
below freezing.
5.
TECHNICAL DATA
Electronic counter
ADPMPD/T, ADP1/T, ADP2/T, ADP1/L
Tankautomat (CRID)
ADAMAT/PNN, ADAMAT/PNA, ADAMAT/EMV
Display
Iluminated LCD - BACK LIGHT DISPLAY (BLD)
ADAMAT - Graphic BLD, Touch screen
Connecting piece – pressure system
DN 25 with external screw G 1“
Minimum innner diameter required
DN 16 (stainless pipe or special rubber hose for AdBlue
®
)
Alternative DN 19 – rubber hose for AdBlue
®
Measured fluid
AUS 32 ISO 22241 (AdBlue
®
)
Accuracy of measurement
± 0,5 %
Max. operating pressure p
max
0,32 MPa
Min. operating pressure p
min
0,12 MPa
Max. flow rate Q
max
40 dm
3
.min
-1
20 dm
3
.min
-1
10 dm
3
.min
-1
Min. flow rate Q
min
4 dm
3
.min
-1
2 dm
3
.min
-1
2 dm
3
.min
-1
Min. measured quantity (MMQ)
2 dm
3
2 dm
3
2 dm
3
Maximum flow rate when dispensing from one
nozzle Q
max
40 ±4 dm
3
.min
-1
(for dispenser 4701.xx0/40)
20 ±2 dm
3
.min
-1
(for dispenser 4701.xx0/20)
10 ±1 dm
3
.min
-1
(for dispenser 4701.xx0/10)
Maximum flow rate when dispensing from both
nozzless simultaneously Q
max
30 ±3/30 ±3 dm
3
.min
-1
(for dispenser 4701.20x/40/40)
30 ±3/5 ±1 dm
3
.min
-1
(for dispenser 4701.11x/40/10)
15 ±2/5 ±1 dm
3
.min
-1
(for dispenser 4701.11x/20/10)
5 ±1/5 ±1 dm
3
.min
-1
(for dispenser 4701.02x/10/10)
Ambient operating temperature
-40 °C to +55 °C
Medium temperature
-10 °C to +50 °C
Filtration ability
Standard 60 µm
Reach of dispensing hose
4,5 m (V-line R)
Max. level of noise
<60 dB
Power supply of electronics
U
nap
P
nap
1/N/PE AC 230 V ±15 % 50 Hz
input 85 VA
Power supply of ADAMAT
electronics
U
nap
P
nap
1/N/PE AC 230 V ±15 % 50 Hz
input 120 VA
Power supply of electronic case
heating
U
nap
P
nap
1/N/PE AC 230 V ± 15 %, 50 Hz
input 250 VA