Setting of unit price values from the control system in AUTO mode
In AUTO mode the unit price values are set from the control system for all transactions independently on
unit price values set for the MAN mode.
The unit price values for the AUTO mode are set for all dispensing points by dynamic statement (command)
"permission to dispense" transmitted from the filling station console or by the "price setting" statement. All
these statements are a part of the specification of the EASYCALL communication protocol.
10.3
Display of electronic totalizers
The ADPMPD/T, ADP 1,2/Tcounter is fitted with non-resettle electronic totalizers of volume and price for
individual dispensing nozzles.
The totalizers can be displayed on the displays of the side by means of the KL-MANINF manager keyboard or
the KL-SERINF service keyboard. The display of the totalizer can be switched by lifting the relevant nozzle.
The sum of the volume (or the sum of the price) is displayed on the displays of the side on the coupled lines
of the total price and total volume.
Both displays of the side display an identical sum.
As the first from the left "
U
" character is displayed on the total price line for the display of the volume
sum and "
A
" character for the display of the price sum.
The second character from the left displays the highest digit position of the relevant sum.
The sixth character from the left displays the lowest digit position of the relevant sum.
The sums are counted and displayed with decimal place count according to the data setting of the counter.
The side number and the nozzle number of the totalizer displayed at this moment are displayed on the unit
price line:
e.g..: 1 - 3...A side - nozzle No. 3;
2 - 1...B side - nozzle No. 1.
Display procedure:
1.
Both dispensing points shall be free (transitions are not running at any of the both points and
terminated transactions shall be acknowledged).
2.
Depress the "
+
" key to display the volume sum. Depress the "
–
" key to display the price sum.
3.
All segments light up and light out on the displays of the sides after depressing the "
+
" key (or the "
–
"
key) (similarly with the transaction starting to checking if all segments display correctly) and total
number of feeding voltage drop-outs is shortly displaced.
4.
Then "
U
" and the volume sum of the relevant nozzle (or "
A
" and the price sum of the relevant nozzle)
are displayed on the displays of sides.
5.
It is possible to carry out the transition to the volume totalizer displays of the next dispensing nozzles
by repeated depressing the "
+
" key or by lifting the relevant nozzle (as well as the transition to the
price totalizer displays of the next dispensing nozzles by repeated depressing the "
–
" key or by lifting
the relevant nozzle).
6.
Terminate the scanning of electronic totalizers by depressing the "
0
" key and in case the thermal and
electronic calibration are activated, transition in the display mode of their setting occurs.
7.
The setting of thermal calibration for relevant nozzle is activated by the ATC text. The setting of
electronic calibration of the relevant nozzle counter is activated by the EC text.
8.
Terminate the scanning by depressing the "
0
" key and return to the standard mode.
Unit price seting
Shift from most significent
digit, side A , nozzle 1
Shift from most significent
digit, side B , nozzle 1