Appendix
Multi-section sign: horizontal split assembly (11800000-16, revision A)
NOTES:
1) REFER TO WIRING DOCUMENTATION 11800000-04, -05, AND -09
FOR PCB CONNECTION DETAILS.
2) AC WIRING IS SPECIFIEC FOR EACH "SPLIT SECTION" SIGN. REFER
TO THAT SIGNS'S AC WIRING DRAWING (SEE WORK ORDER).
C4
DETAIL D
SCALE 1: 8
A
B
C
D
4
3
3
4
C2
C1
Wy
C3
C1
C2
C3
C4
Wx
TIE WRAP DTURBO TO
ANCHOR, 63100029.
SEE DETAIL A FOR
LABELING.
Wx
Wy
REMOVE
BACKING
FOLD OVER
ALONG
DASHED LINE
DB25
FROM Ca
APPLY LABEL
9800760x
DB25
67010014A LOCTITE SHOULD NOT
COME IN CONTACT WITH PLASTIC!
FROM Cb
APPLY LABEL
9800760x
DETAIL A
SCALE 1: 2
SECURE GROUND WITH
NUT (61620025). SECURE
CABLE TO INSIDE WALL OF
DISPLAY CUBE WITH A TIE
WRAP PAD (63101056)AND
A TIE WRAP (63100008).
THREAD NUT (61620025),
FOR GROUND CABLE.
GROUND CABLE TO
BE CONNECTED IN FIELD.
CUT ALONG
CENTER LINE
63020756 SPACER