September 28, 2004
AlphaEclipse 3600 Series A Sign Installation Instructions (9711-8001C)
60
Appendix
Multi-section sign: vertical/horizontal split assembly (11800000-17, revision A, sheet 2 of 2)
DETAIL A
SCALE 2 : 1
INSERT 2 GROMMETS
(63120013) PER SIGN ROW
INTO POLY BAG (92005212).
HEAT SEAL POLY BAG SHUT.
SECURE BAG WITH PACKING
TAPE TO TOP ANGLE
BRACKET OF SIGN SECTION
THAT CONTAINS THE WIREWAY.
DETAIL B
SCALE 1 : 3
DETAIL C
SCALE 1 : 3
DETAIL F
A
B
C
D
4
3
3
4
DB25
FROM Ca
APPLY LABEL
9800760x
DB25
67010014A LOCTITE SHOULD NOT
COME IN CONTACT WITH PLASTIC!
FROM Cb
APPLY LABEL
9800760x
63020756 SPACER
SECURE GROUND WITH
NUT (61620025). SECURE
CABLE TO INSIDE WALL OF
WIREWAY WITH A TIE
WRAP PAD (63101056)AND
A TIE WRAP (63100008).
THREAD NUT (61620025),
FOR GROUND CABLE.
GROUND CABLE TO
BE CONNECTED IN FIELD.
CENTER LABEL 98118028 OVER
OPEN HOLES ON BOTH UNITS.
SEE DETAIL D.
DO NOT PREP SURFACE.
INSTALL PRIOR TO CRATING,
AFTER TESTING. FOR ALL CUBES.
DETAIL D
SECT
ION
LOCA
TION
98118029. LABELED
RIGHT OR LEFT.
FOR LINE 1 ONLY.
98008881, 98008882,
OR 98008883. SEE BOR.
63120013
REMOVE
BACKING
FOLD OVER
ALONG
DASHED LINE
CUT ALONG
CENTER LINE