September 28, 2004
AlphaEclipse 3600 Series A Sign Installation Instructions (9711-8001C)
44
Appendix
Mechanical installation (11800000-07 revision F, sheet 1 of 5)
4
3
2
2
3
4
SOCKET HEAD CAP SCREWS.
OPEN WITH 5/32 HEX TOOL
(PROVIDED).
NOTE: DESIGN AND DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. SEE SHEET 2 FOR ADDITIONAL NOTES.
22.05 WIREWAY
B
(SEE SHEET 2)
6.34 WIREWAY BOX.
LEFT WIREWAY OPTIONAL.
LOCATION TO BE SPECIFIED
AT TIME OF ORDER.
A
(SEE SHEET 2)
B
B
FRONT VIEW
FRONT ACCESS
TO POWER AND
SERIAL DATA
CONNECTIONS
VIA WIREWAY BOX.
CONTROLLER LOCATED IN SECOND
CUBE FROM WIREWAY IN BOTTOM ROW.
WIREWAY CONDUIT ENTRY
KNOCKOUTS PROVIDED.
DO NOT RUN RS485 POWER
AND DATA CABLE IN THE
SAME CONDUIT. POWER AND
FIBER OPTIC CAN BE RUN
IN THE SAME CONDUIT IF
NECESSARY.
ONE ENCLOSURE CUBE
CONSISTS OF FOUR
DISPLAY MODULES.
RS485 CONNECTOR
SERVICE DOOR ACCESS
(ALLOW 18.5" MINIMUM.
REAR ACCESS IS OPTIONAL.)
1.00
18.5
.79
1.19
6.87
3.00
11.85
TOP VIEW
REAR ACCESS
FRONT ACCESS
4.00
19.87
22.05 TYP.
1.18 TYP.
.36 TYP.
7.35 TYP.
7.35 TYP.
19.29 TYP.
1.38 TYP.
2.76 TYP.
7.35 TYP.
4.67 TYP.
3.67 TYP.
L2x3x¼, A36 STEEL
PAINTED BLACK
4x¼, A36 STEEL PAINTED
BLACK (BETWEEN EACH
ROW.) DO NOT ATTACH
MOUNTING STRUCTURE TO
THESE MEMBERS.
(SEE NOTE 5.)
IF REAR DOOR ACCESS IS
NEEDED, MOUNT TO
VERTICAL STRUCTURES IN
THIS AREA ONLY TO AVOID
BLOCKING DOOR. (SEE
NOTE AT LOCATION D-3.)
CRS STEEL FORMED ANGLE
POWDER COAT BLACK
L2x3x¼, A36 STEEL
PAINTED BLACK
BACK VIEW
BOLTS AND NUTS MUST NOT
BE REMOVED OR REPLACED.
(SEE NOTE 3.)
OPTIONAL
CONDUIT
LOCATIONS.
(AS
INDICATED
ON
WIREWAY.)
OPTIONAL FLATHEAD SCREWS
ARE USED WHEN SIGN
SECTIONS ARE CONNECTED
TOGETHER INTO LARGER
SIGN SECTIONS. CONTACT
ADAPTIVE FOR DETAILS.
(SEE PAGE 3.)
EXHAUST VENTS TYP.
(SEE NOTE 8.)
INTAKE VENTS TYP.
(SEE NOTE 8.)