Appendix
45
AlphaEclipse 3600 Series A Sign Installation Instructions (9711-8001C)
September 28, 2004
FRONT DISPLAY ACCESS
NOTES:
1) REFER TO INSTALLATION MANUAL FOR POWER AND ADDITIONAL INSTALLATION REQUIREMENTS.
2) THE ONLY SERVICE TOOLS REQUIRED ARE A #2 PHILLIPS SCREWDRIVER, 5/32 HEX TOOL
(PROVIDED), AND A TECHNICIANS SLOTTED BLADE SCREWDRIVER (PROVIDED).
3) REMOVAL OF ANY FASTENERS OR OTHER NOTED PARTS WILL NEGATE THE PRODUCT WARRANTY.
4) ALL FASTENERS ARE METRIC A2 STAINLESS STEEL.
5) USE ONLY TOP AND BOTTOM ANGLE OR VERTICAL ANGLES TO MOUNT SIGN DIRECTLY TO
SUPERSTRUCTURE. ALL INSTALLATIONS, SUPERSTRUCTURE DESIGNS, AND CONNECTIONS MUST
BE DESIGNED/APROVED BY A QUALIFIED STRUCTUAL ENGINEER. CALL ADAPTIVE MICRO SYSTEMS
AT 1-800-558-7022 FOR STRUCTURAL ENGINEERING CONSULTANT CONTACT INFORMATION.
6) DUE TO STREGTH LIMITATION OF DISPLAY SUBSTRUCTURE, LARGER SIGNS WILL REQUIRE MULTIPLE
DISPLAY SECTIONS. DISPLAY SECTION SIZE WILL BE OPTIMIZED FOR PRODUCTION YIELD AND MAY
VARY WITH EACH SIGN. (SEE SHEET 3.)
7) DESIGN AND DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
8) IF SIGN IS BUILT INTO AN ENCLOSED STRUCTURE, INTAKE AND EXHAUST AIR SHALL BE PROPERLY
VENTED TO PREVENT MIXING AND RECIRCULATION OF EXHAUST AIR WITH THE INTAKE AIR.
E
REV.
DESCRIPTION
ECO
BY
DATE
F
UPDATED BORDER TEMPLATE
8744
RD
M
9/13/2004
E
ADDED FIBER OPTIC NOTE FOR DRILLING
8642
DRZ
3/11/04
D
ADDED NOTE 8 TO SHEET 1
8622
SSL
3/1/04
C
CHANGE DIMESNION "A" TO INCLUDE WIREWAY
8541
SSL
2/3/04
B
ADD ELECTRICAL REQUIREMENTS TO SHEETS 4 AND 5.
UPDATE WEIGHTS IN CHART ON SHEET 2.
8526
SSL
1/22/04
A
RELEASED FOR PRODUCTION. ADDED SHEET 3 FROM
REV P05. MODIFIED NOTES AND TABLE ON SHEET 2.
-
SSL
9/4/03
7840 North 86th Street
Milwaukee, WI 53224 USA
SHT
DOCUMENT NO.
C
SIZE
TITLE
REVISION
APPROVED BY
DESIGNED BY
DATE
DATE
SCALE:
DIMENSIONS ARE INCH AND TOLERANCES ARE
AS FOLLOWS UNLESS OTHERWISE SPECIFIED
DATE
DRAWN BY
ALPHA ECLIPSE 3600 MECHANICAL DETAILS
11800000-07
1:10
1 of 5
F
Released
STATUS:
±0.1
±0.02
±0.005
±1°
.X
.XX
.XXX
ANGLES
D
C
B
A
2
1
1
2
THIS DRAWING IS THE PROPERTY OF ADAPTIVE MICRO SYSTEMS LLC AND SHALL NOT BE DUPLICATED WITHOUT PERMISSION
SSL
9/14/03
SSL
9/14/03
6.68 WIREWAY BOX
11.0
LIGHT
SENSOR
LOCATION
2.5
14.0
1.0
1.5
2.8
3.5±.5
6.00
A
RIGHT SIDE VIEW
OPTIONAL:
DRILL HOLES
FOR POWER
AND DATA
ENTRY HERE.
WARNING!
LIFTING BRACKETS TO BE USED PER
INSTALLATION MANUAL ONLY.
LIFTING BRACKETS TO BE USED TO LIFT SIGN
ONLY. DO NOT LIFT SIGN IF IT IS STILL
ATTACHED TO THE SHIPPING CRATE.
LIFTING BRACKETS DESIGNED FOR
INITIAL INTALLATION ONLY AND
SHOULD BE REMOVED AFTER SIGN
IS INSTALLED.
CENTER OF
GRAVITY
RESERVED
FOR FIBER OPTIC
MODEM OPTION
**DO NOT DRILL IN
THIS AREA**
DISPLAY DETAIL
SCALE 1:4
5/32 HEX TOOL ACCESS
HOLE. TURN HEX TOOL
(PROVIDED) 180º
COUNTERCLOCKWISE
TO REMOVE 8x8 DISPLAY.
.38 LOUVER
DEPTH
.08 CASE
THICKNESS
SECTION B-B
POLYCARBONATE
DISPLAY LOUVER
.25
3.00
DETAIL A
SCALE 1 : 4