22
ActronConnect Installation & Commissioning Guide - Website
Doc. No.9590-1001 Version No.3.0 150901C
WIRING DIAGRAM
R
T
h
is draw
ing remains t
h
e int
ellect
ual
propert
y
of
Act
ron Engineering
Pt
y
Lt
d.
Reproduct
ion,
modif
icat
ion
and/
or dist
ribut
ion
are prohibit
ed
w
it
h
out
w
rit
ten consent
.
Revision
Descr
ipt
ion
:
Dr
awing No:
A
WD2004
Rev.
Description
Date
By
PCR
ORIGINAL
A4
Siz
e
:
Base
Model No:
Variat
ion:
Variat
ion Code:
A
ERM EVAPORAT
O
R WIT
H EC FAN MOT
O
R
& OPT
IONAL ACM WIFI MODULE & POWER SUPPLY
LEGEND
AM
IB
ACM
EXV
IF
IFRC
TX
WC
EM
C
F
8Z
-VAV
05-11-2013
MH
Drawn:
Date:
Approved:
MJH
Date:
05-11-2013
NEUT
NEUT
LINE 1
ACT
CB-1
10 A
FIELD W
IRING BY
INST
A
LLER
SCRN
COM
PWR
KEY
COM
DATA
EART
H
NEUT
ACT
INDOOR
C
O
IL
IN
SENSO
R
OUT
DOOR
IF-
1
1
EC
EC
CONT
ROL
EC
M
CONTRO
L
M
O
DUL
E
INDOOR FA
N (IF)
IN
T
E
RNA
L
A
U
T
O
RESET
O
VERL
O
A
D
PRO
T
ECT
IO
N
FERRIT
E
EM
C-
1
E
N
A
N A
PCB JUMPER PIN
POSITION TA
BLES
Jumper Pin
Position
A/
C
M
o
d
e
l
D
PCB M
odel:
A
M
IB-PVVM
C
B
A
E
ERM
3
-17A
S
ERM
4
-19A
S
N/A
N/A
ERM
2
-14A
S
(+) A
B (-)
PO
W
E
R
COM
KEY
SENSOR
PO
W
E
R
COM
KEY
SENSOR
DO
NO
T
CO
NNE
CT
SC
R
EEN
A
N
D
SEN
SO
R
AT
W
A
L
L
CO
NTRO
L
SEE J
U
M
PER
PI
N PO
SI
TI
O
N
T
A
BL
ES F
O
R
CORRECT
SET
T
ING
UL
T
IM
A
M
O
DUL
E
(8Z-VAV)
AM
IB
DA
T
A
ZO
NE
8
ZO
NE
7
ZO
NE
6
ZO
NE
5
ZO
NE
4
ZO
NE
3
ZO
NE
2
ZO
NE
1
TO
Z
O
N
E
2
-
8
240V
MA
INS
ZONE
MO
TO
R
ZONE
CONT
ROL 1
ZONE
SENSOR 1
LOG
RJ45
SO
CKET
S
FO
R
A
C
T
R
O
N
A
IR
CA
T
5
E SPEC
CA
BLES O
N
LY
FIELD WIRING
FERRIT
E
(IF FIT
T
E
D)
S
C
R
EEN
WI
R
E
S
DA
T
A
CA
BLE SCREEN W
IRE -
KEEP A
S
SHORT
A
S
POSSIBLE
MA
INT
A
IN T
W
IST
E
D
PA
IR
UNT
IL T
E
RMINA
L
O
N
A
M
IB
FIELD W
IRING BY INST
A
L
LER -
CA
BLE MUST
BE 2 CORE 7/0.30 SHIELDED T
W
IST
E
D PA
IR DA
T
A
CA
BLE
W
IT
H
SCREEN W
IRE CONNECT
ED T
O
T
H
E SCREEN T
E
RMINA
L
ON INDOOR UNIT
& SCREEN FOIL CLA
M
PED T
O
P-CLIP ON OUT
D
OOR UNIT
+V
-V
N
A
A
C
IN
DC OUT
AD
J
A
C
M
POWER
SUPPLY
(240VA
C
-
12VD
C
1.3A
)
BROWN
BLUE
GR
EEN /
YEL
LO
W
BRN /
WH
IT
E (G
REE
N)
BROWN
IM
PO
RT
A
N
T
:
DO
NOT M
O
UNT
W
IFI M
O
DULE
DIRE
CTLY
O
N
E
V
A
P
O
RA
TO
R UNIT
- FOR OP
TIM
UM
P
E
RFORM
A
NCE
OF
W
IF
I S
IG
N
AL
M
O
U
N
T
1
M
E
T
R
E
AW
AY
&
N
O
T A
B
OV
E
E
V
A
P
OR
A
T
OR
- MO
U
N
T
MI
N
IMU
M 1
ME
T
R
E
B
E
L
O
W
RO
O
F
WIFI
MODULE
3G LPW WIFI ETH
E2
RST
MO
D
E
ET
H
A
C
PW
R
P1
A
N
T
E
NNA
BRO
WN
BLUE
BROWN
BLU
E
DAT
A
IMPORT
ANT :
DO NOT MOUNT
ACM DIRECTL
Y
ON INDOOR UNIT
.
- FOR OPTIMUM PERFORMANCE OF W
i-Fi SIGNAL
MOUNT 1 METRE
A
W
A
Y
(OR GREA
TER)
AND
NOT
ABOVE THE INDOOR UNIT
.
- MOUNT MINIMUM 0.5 METRE BELOW ROOF LINE.