ActronConnect Installation & Commissioning Guide - Website
Doc. No.9590-1001 Version No.3.0 150901C
Step 1.2.2.
Do not place the ActronConnect module where it can be easily damaged by accidentally
stepping on it or where it can be covered by ceiling insulation.
Step 1.2.3.
Refer to the module mounting diagram - Requirements for ACM Optimum Signal Performance,
for the best mounting direction of the module based on your particular installation requirement.
Step 1.2.4.
Refer to the wiring diagram for the cable connections on pages 29 - 33.
Step 1.2.5.
Take the ActronConnect module 3m Grey Data Cable running from the indoor electrical panel
& run it to the installed module, ensuring it is in a position where it cannot be easily damaged and it is at
least 300mm away from any other installed cables (i.e. power, lights, PC data, TV antenna, etc.). If it is
impossible to avoid running the ACM data cable close to the other cables, run it across the other cables
at 90 degree (do not run in parallel).
Run the ACM data
cable from the Indoor
Unit to the ACM
3m ACM
Data Cable from the
Indoor Unit
ActronConnect
Module
Step 1.2.6.
Secure the 3m Grey Data Cable to the timber roof joist or similar with the cable ties or other
suitable cable fi xing fasteners. Do not loop any excess cable in a tight loop. Leave it loose.
Strong possibility of communication problems.
The “
loops
” can cause an electro-magnetic
interference, upsetting data communication.
No electro-magnetic interference.
Keep communication cable at least 300mm
from high voltage cables.
Do
NOT
loop excess cable
RUN
data cable as straight
and short as possible
NOT RECOMMENDED
RECOMMENDED