Step 1.1.4.
Refer to the wiring diagram for the cable connections on pages 29 - 33.
Step 1.1.5A.
Step 1.1.5B.
(Classic, ESP Plus & ESP Platinum Plus Models) (ESP Ultima & ESP Platinum Ultima Only)
“PLUG A”
2 Pin Power
Connector
P1
2 Pin Socket
“PLUG A” 2 Pin Power
Connector
P1
2 Pin Socket
Auxiliary Power
Socket
Ultima Power
Connector
Connect “PLUG A” (2 Pin Power Connector) for the
230VAC of the power supply into the corresponding
2 Pin Socket labelled “P1 (240VAC)” on the Indoor
PCB AMIB. (This plug only goes in one way, ensure
it is in correct orientation before pushing it all the
way in).
Unplug Ultima 2 Pin Power Connector from “P1”
and connect “PLUG A” as in Step 5A above.
Then, plug the Ultima power connector into the
auxiliary power socket.
Step 1.1.6.
Connect “EARTH RING LUG” to the earthing bolt of the indoor unit electrical panel. Unscrew
the nut, remove the washer & slide the EARTH RING LUG over the bolt making sure all of the existing
earthing lugs remain connected. Replace earthing washer & nut and tighten the nut securely.
ACM
Earth Wire
Existing
Earth Wires
Earthing Bolt
& Washer
Step 1.1.7.
Connect “PLUG B” (4 Pin JST) for the data of ActronAir Connect Module into the
corresponding 4 Pin Socket labelled “J4 DATA” on the Indoor PCB AMIB. (This plug only goes in one
way, ensure it is in correct orientation before pushing it all the way in).
ACM
“PLUG B”
(4 Pin JST)
J4 DATA
(4 Pin Socket)
DATA
DATA
Indoor