Step 1.1.8.
Take the “PLUG C” (RJ45 Data) for the ActronConnect Module & run it out from the indoor
electrical panel via the large cable gland on the right side of the electrical panel. Feed the data cable all
of the way out so that only a minimum cable length remains inside the panel. Using cable ties, secure the
cable to the electrical panel and into the zone cables exiting from the same cable gland.
Large
Cable Gland
Run the ACM data
cable out from the
electrical panel
NOTE:
For optimum performance & module communication integrity, keep the ActronConnect
Module data cable as far as possible from the 230VAC mains.
Step 1.1.9.
Take the wiring diagram with adhesive back, peel off adhesive protection strip & stick the wiring
diagram unto the front the electrical panel lid.
Indoor Unit
Lid- Electrical
Panel
Electrical Panel
Wiring Diagram
Step 1.1.10.
Check all connections and screw lid back onto indoor electrical panel.