3
ActronConnect Installation & Commissioning Guide - Website
Doc. No.9590-1001 Version No.3.0 150901C
The instructions herein refer to work involving a Computer CPU
•
Chip & Electronic CPU Board, please ensure all Instructions are
followed accurately so as to prevent damage to these fragile & delicate
components.
CODES, REGULATIONS & STANDARDS
The installer and/or contractor assumes responsibility to ensure that
ActronConnect Module installation and commissioning comply with the
relevant council, state / federal codes, regulations and building code
standards.
All electrical wiring must be in accordance with current
electrical authority regulations and all wiring connections to be as
per electrical diagram provided with the unit.
SPECIFICATIONS
ActronConnect Module Part No. ACM-1
Wi-Fi Protocol
802.11b/g/n
Operating System Requirement
IOS 6.1.3 or later version
Security Protocol
Web-128, WPA-PSK, WPA2-PSK
Hardware Voltage
9VDC - 15 VDC
Max. Operating Temperature
60
o
C
IP Rating
IP20
Max Cable Length from ACM to
Power Supply Kit
10 metres
Access Point Distance
*
15 metres
Wi-Fi Range
70m line of sight
*
The maximum
distance that can be established between ACM and mobile device
(i.e. iphone, ipad, laptop) if the mobile device is acting as an access point.
Power Supply Part No. 2020-200K
Output Ratings
12VDC 1.3A 15.6W
Input Ratings
85
~
264VAC 120
~
370VDC
- Frequency Range
47
~
63Hz
- Inrush Current
Cold Start 65A / 230VAC
- Effi ciency (Typical)
81%
- AC Current (Typical)
0.35A / 115VAC
0.25A / 230VAC
Working Temperature
-20
~
+70
o
C
Working Humidity
20-90% RH
non-condensing
Overload Protection
Above 105% Rated Power
O/L Protection Type
Hiccup mode, auto recovery after
fault condition is removed
Over Voltage Protection
13.8-16.2V
O/V Protection Type
Shut-Off o/p voltage, clamping by
zener diode