7
ActronConnect Installation & Commissioning Guide - Website
Doc. No.9590-1001 Version No.3.0 150901C
1.2 ActronConnect Module Installation Procedures:
IMPORTANT NOTE:
ActronConnect Module CANNOT be installed on the sheet metal
part of the indoor unit (particularly at the top) as the performance & integrity of the
wireless signal will be greatly reduced.
Step 1.2.1.
Install the ActronConnect Module to a suitable secure location, like a roof joist or similar using
the supplied screws. Keep the module at least 0.5m away from the roof line and 1m from the indoor
unit, large metal objects or other sources of interference (e.g. antennas, exhaust fans, duct work, etc.).
Also ensure it is kept away from potential sources of dust, heat & moisture (i.e. light fi xtures, heaters,
bathroom exhaust fan outlets, etc.)
NOTES:
1.
Maximum Allowable Cable Length between the indoor unit and the ActronConnect module is 10m
. This can be
achieved with the use of a 2-Way Joiner PN: 2045-121 (Sold Separately) and a 7m ACM extension cable PN: 4070-027
(Sold Separately). The Actron Power Supply kit comes pre-wired with 3m cable. Do not run ACM cable in parallel with the
240V power supply cable and keep 300mm minimum distance from other cables (mains, data, antenna, etc).
2.
DO NOT USE Actron CAT5E zone cables to extend ACM cables.
3. Locate the ActronConnect Module as close as possible to the ceiling and the manhole for ease of access, ensuring that
LED is facing towards the manhole and that the roof insulation does not come into contact with the module.
4. Do not install ActronConnect Module in roof cavities where temperature can exceed 60
o
C. In the event where you require
to install the Actron Connect Module below the ceiling line (Eg. Storage cabinet), please ensure you use an appropriate
plastic enclosure (supplied by others) that complies with all relevant safety codes, regulations and standards.
DETAIL - “A”
Roof Joist
Securely run cables along the roof
joist and at least 300mm away from
any other installed cable (i.e. power,
lights, PC data, TV antenna, etc.)
ActronConnect
Module
Secure the ActronConnect
Module to the roof joist using
the supplied screws.
ACTRONCONNECT MODULE INSTALLATION DIAGRAM
Manhole
1m>
Do Not Install the ActronConnect
Module on top of the indoor unit
ActronConnect Module
Roof
0.5m>
A
Indoor Unit
w.i.r
Install the ActronConnect Module 1m
away (or greater) from the Indoor unit .
Install the ActronConnect Module 0.5m
away (or greater) from the roof line.
See notes 3 & 4 for
ActronConnect Module
location requirements.
Return
Air Grille