AR-B1380/AR-1380A User’ s Guide
Page 30
(3) JP1 & JP4: External RS-485 Adapter Selector
JP1 and JP4 can be set independently. JP1 selects COMB port and JP4 selects COM A port. JP4 selects
the external RS-485 for COMB port connecting with CN7. JP4 selects the external RS-485 for COMA
connecting with DB2.
JP1/JP4
RS-485 Adapter Selector
JP1: CN5
JP4: DB2
1-2
Reserved for Acrosser’ s RS-
485 Adapter
2-3
(Factory Preset)
RS-232C
Table 3-12 JP1 & JP4: External RS-485 Adapter Selectors
(4) CN5 & DB2: RS-232C Connector
There are two serial ports with an EIA RS-232C interface on the AR-B1380/AR-B1380A. COM A uses one
on-board D-type 9-pin male connector (DB2) which is located at the top of the card, and COM B uses one
10-pin header (CN5). Use the BIOS Setup program to configure these two serial ports, and adjust the
jumpers on JP1 and JP4.
CN5
DB2
Signal
CN7
DB2
Signal
1
1
-DCD
2
6
-DSR
3
2
RXD
4
7
-RTS
5
3
TXD
6
8
-CTS
7
4
-DTR
8
9
-RI
9
5
GND
10
--
Not Used
Table 3-13 Serial Port Pin Assignments
Note: CN5 can be configured for RS-232 or RS-485. When it is RS-485 compatible, you must set
JP11 to “1-2, 4-5, 7-8” and JP1 to “1-2.”
3.3.13 LED Headers and Indicator
This system provides LED headers and a LED indicator for the users to easily monitor the system’ s
operation.
(1) J6: External Power LED Header
J6 is used to connect to the external power LED.
Summary of Contents for AR-B1380