Before installing the drive check that the door is in good mechanical condition and that it
is correctly balanced. Check that it opens and closes properly.
Install the release control at a maximum height of 1.8 m.
Any fixed controls must be installed within sight of the door but away from moving parts.
It must be installed at a height of at least 1.5 m.
Attach a label near the operating device, in a permanent fashion, with information on
how to operate the manual release.
Permanently fix a label warning against entrapment in a prominent place or just near
any fixed control.
The motor cannot be installed on panels incorporating doors (unless the motor can be
activated when the door is open).
Following the assembly please ensure that the door elements do not project out on
public footpaths or roads
The drive is intended to be installed at least 2.5m above the floor.
Do not install the gearmotor in presence of fumes or inflammable gas.
The mechanical parts must conform to the provisions of standard EN 12604 and EN
12605.
Manufacturer is not responsible for failure to observe good technique in the construction
of the closing elements to be motorised, or for any deformation that may occur during
use.
The installation must conform to standards EN 12453 and 12445.
WARNING: Before start any job on the system, cut out electrical power.
The mains power supply of the automated system must be fitted with an all-pole switch
with contact opening distance of 3mm. Use of a 6 A thermal breaker with all-pole circuit
break is recommended.
Make sure that the earth system is perfectly constructed.
The safety devices (photocells , etc.) protect any danger areas against mechanical
movement risks, such as crushing, dragging, and shearing.
Use of at least one indicator-light is recommended for every system, as well as a
warning sign, in addition to the safety devices.
Do not command more than one gearmotor with each button.
For maintenance, exclusively use original parts.
Do not in any way modify the components of the automated system.
The mains cable must only be replaced by the manufacturer, customer service or
another qualified person. For connection to the mains power supply, use a multicore
cable with a cross-section between 3x0.75mm
2
and 3x1.5mm
2
.
The installer shall supply all information concerning manual operation of the system in
case of an emergency, and shall hand over to the user the warning handbook supplied
with the product.
Apply safety devices that meet standard EN 12978 to provide full protection against
impact, crushing and shearing in conformity with the provisions of standard EN 12453.
The installation must include a fall arrest system for the shutter, such as the parachute
shown in the instructions.
Do not allow children or adults to stay near the product while it is operating.
Keep radio controls or other pulse generators away from children, to prevent the
automated system from being activated involuntarily.
The user must not attempt any kind of repair or direct action whatever and contact
qualified personnel only.
Transit is permitted only when the automated system is idle.
Maintenance: check at least every 6 months the efficiency of the system.
Sound emission: LpA ≤ 70dB;
Anything not expressly specified in these instructions is not permitted.