3 System upgrades
42
(4) Engage the load lever back into place.
8
Apply the thermal interface material.
(1) Use an alcohol pad to wipe off the old thermal grease
from both the heat sink and the processor socket
retention plate.
(2) Apply a thin layer of an approved thermal interface
material before installing the heat sink.
Make sure that only a very thin layer is applied so that
both contact surfaces are still visible.
9
Install the heatsink (see “Installing a heatsink” on page 38).
10 Observe the post-installation instructions described on page 25.
11 Repeat the steps above to replace the second processor.