Installation and Operation Manual
Chapter
6 Monitoring and Diagnostics
ACE-3105, ACE-3205 Ver. 5.2
Monitoring Performance
6-7
Parameter Description
Possible
Values
•
Holdover – An idle timing mode in which
the internal clock chip reinstates the
timing of the previously active
master/fallback clock source.
For more information about these clock
states, refer to
Appendix D
.
Recovered ID
ID of the recovered clock stream
1
³
To view the recovered clock statistics:
•
From the Recovered Clock menu, select Statistics.
The recovered clock statistics are displayed.
ACE-3205 – RAD Data Communications
Monitoring> System> Clock> Recovered clock> Statistics
RX packets ... (93814)
Lost packets ... (0)
Out of order packets ... (0)
Buffer underflow ... (0)
Time elapsed ... (100)
Valid intervals ... (1)
1. Interval ... (0)
2. Recovered ID ... (1)
PW number ... (1)
>
Please select item <1 to 2>
ESC-previous menu; !-main menu; &-exit
Figure
6-9. Recovered Clock Statistics
Table
6-6. Recovered Clock Statistics Parameters
Parameter Description
Possible
Values
RX packets
Number of good clock packets that have
been received
Numerical
Lost packets
Number of lost clock packets
Numerical
Out of order
packets
Number of detected out-of-order packets
Numerical
Buffer underflow
Number of underflow events that have
occurred in the clock stream buffer
Numerical
Time elapsed /
Start time
Elapsed time (in seconds) since the
beginning of the current interval.
Start time is for intervals 1–24.
0–899