Fieldbus Interface
114
Table 1: Guide Point Offset and Web Position ranges
Guide Point Offset
Web Position
Sensor
Type
Sensor Model
Number
Range
inches
[mm]
Min
Value
decimal
Max
Value
decimal
Range
inches
[mm]
Min
Value
decimal
Max
Value
decimal
1.5x3U 4043-XX
0.064
[1.63]
16352
[3FE0]
16416
[4020]
0.255
[6.48]
16256
[3F80]
16511
[407F]
3x3U 4050-XX
0.064
[1.63]
16352
[3FE0]
16416
[4020]
0.255
[6.48]
16256
[3F80]
16511
[407F]
4x6U 4060-XX
0.064
[1.63]
16352
[3FE0]
16416
[4020]
0.255
[6.48]
16256
[3F80]
16511
[407F]
Po
in
tSou
rce
Ultraso
n
ic
E/D
4x12U 4090-XX
0.064
[1.63]
16352
[3FE0]
16416
[4020]
0.255
[6.48]
16256
[3F80]
16511
[407F]
1.5x4U 4510-XX
1.600
[40.64]
15584
[3CE0]
17184
[4320]
1.800
[45.72]
15484
[3C7C]
17284
[4384]
1.5x5U 4511-XX
2.400
[60.96]
15184
[3B50]
17584
[44B0]
2.600
[66.04]
15084
[3AEC]
17684
[4514]
4x5U 4500-XX
2.400
[60.96]
15184
[3B50]
17584
[44B0]
2.600
[66.04]
15084
[3AEC]
17684
[4514]
4x9U 4520-XX
6.400
[162.56]
13184
[3380]
19584
[4C80]
6.600
[167.64]
13084
[331C]
19684
[4CE4]
4x14U 4530-XX
11.200
[284.48]
10784
[2A20]
21984
[55E0]
11.400
[289.56]
10684
[29BC]
22084
[5644]
Ultraso
n
ic
W
id
eArray
E/D
4x21U 4540-XX
18.400
[467.36]
7184
[1C10]
25584
[63F0]
18.600
[472.44]
7084
[1BAC]
25684
[6454]
Hi-Temp
Ultraso
n
ic
E/D
UT 4068-XX
0.064
[1.63]
16352
[3FE0]
16416
[4020]
0.255
[6.48]
16256
[3F80]
16511
[407F]
1.5x3L 4044-XX
0.064
[1.63]
16352
[3FE0]
16416
[4020]
0.255
[6.48]
16256
[3F80]
16511
[407F]
Po
in
tSou
rce
In
frared
E/D
3x3L 4051-XX
0.064
[1.63]
16352
[3FE0]
16416
[4020]
0.255
[6.48]
16256
[3F80]
16511
[407F]
1.5x3.75L 4611-XX
1.200
[30.48]
15784
[3DA8]
16984
[4258]
1.400
[35.56]
15684
[3D44]
17084
[42BC]
4x3.75L 4620-XX
1.200
[30.48]
15784
[3DA8]
16984
[4258]
1.400
[35.56]
15684
[3D44]
17084
[42BC]
In
frared
W
id
eArray
E/D
4x14L 4532-XX
11.200
[284.48]
10784
[2A20]
21984
[55E0]
11.400
[289.56]
10684
[29BC]
22084
[5644]
Digital
Line
Guide
P/E 5100-XX
0.426
[10.82]
16171
[3F2B]
16597
[40D5]
0.625
[15.88]
16071
[3EC7]
16696
[4138]
[continued on next page]
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for MICRO 4000 NET
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 141: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 142: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 143: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 144: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 145: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 146: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 147: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 148: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 149: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 150: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 151: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 152: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 153: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 154: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...