Excessive web curl.
If web flutter or curl exists, change parameters 6 and
18 to higher values. Refer to page
12
17 for more information about setting
controller parameters.
All actuators. End-of-travel mode is incorrect.
Set parameter 2 to the
correct value. Refer to page
13
17 for more information about setting controller
parameters.
14
All actuators. Actuator cable wires are broken, shorted or connected
to wrong terminals of J5.
Refer to the connection diagrams on page 137.
Check wiring at J5 and check the actuator cable for broken or shorted
wires.
15
Actuators with potentiometer feedback (MT, SF, HL, HF, HT, and UHT).
End-of-travel limits not set correctly.
Parameters 9 and 10 must be
adjusted to stop the actuator before the web guide or actuator hits any
obstruction. Refer to page 17 for more information about setting controller
parameters.
16
Actuators with potentiometer feedback (MT, SF, HL, HF, HT, and UHT).
Potentiometer failure.
Refer to the potentiometer replacement procedure
on page 86.
17
Actuators with limit switches (MM, MME, MN, and MNE). Limit switch
failure.
Check the limit switch voltage at J5 terminals 5 and 6 (terminal 10
is GND). This voltage should normally be 0.0 VDC (switch is closed), then
jump to +5.0 VDC when the limit is reached (switch opens). If the correct
voltages are not present, replace the limit switch in the actuator or return
the actuator for repair.
Actuators with limit switches (MX). Limit switch failure.
The end-of-
travel limit switches in the MX-series actuators directly control the motor
circuit and cannot be monitored externally. If a limit switch has failed,
replace the switch or return the actuator for repair.
18
Reversed motor wires.
Restore the motor wire connections at J5
terminals 1 and 2 to the proper connection. Refer to the connection
diagrams on page
19
137. Change the value of parameters 3, 4, or 50 as
required. Refer to page 17 for more information about setting controller
parameters.
Edge detector not calibrated.
Refer to page
20
58 for calibration instructions.
Edge detector: transducers covered with dust or other material.
Clean
the edge detector transducer face with a cloth dampened with water or a
mild detergent solution. If the contamination cannot be removed with this
method, return the edge detector for repair.
21
Digital line guide: optics covered with dust or other material.
Clean the
underside of the sensor with a soft cloth dampened with water or a cleaning
solution suitable for photographic lenses. If the contamination cannot be
removed with this method, return the sensor for repair.
Edge detector failure.
Observe the value of parameter 14 or 15 as
required. If this value is below 100, the edge detector is failing and must be
returned for repair. Refer to page
22
17 for more information about displaying
controller parameter settings.
Auto-mode speed limit setting is incorrect.
Change the value of
parameter 7. Refer to page
23
17 for more information about setting controller
parameters.
MICRO
4000
®
NET
Web Guide Control System
13
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for MICRO 4000 NET
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 141: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 142: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 143: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 144: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 145: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 146: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 147: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 148: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 149: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 150: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 151: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 152: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 153: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 154: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...