DGA-6000 ULTRA-HD VIDEO GENERATOR / ANALYZER USER MANUAL
8
IR Remote Control Functions
The AccuPel DGA-6 IR (Infrared) Remote Control provides selection of all calibration patterns, signal
settings, and analyzer functions of the AccuPel DGA-6000. It is also used to navigate and select settings in
the DGA-6000 On-Screen Display (OSD) menus.
The DGA-6000 inactive Format LEDs flash each time a valid IR remote control command is received. A
slowly blinking LED indicates that a special feature mode is active (e.g. Slow Edges).
Output Selection
Directly select the Output type for digital video signals.
YCbCr 444 -
Selects YCbCr 4:4:4 digital video signals. *
YCbCr 422
- Selects YCbCr 4:2:2 digital video signals.
*
RGB-V
- Selects RGB-Video digital video signals. *
RGB-PC
- Selects RGB-PC digital video signals. **
* Y,R,G,B 64-940 (10-bit) or 16-235 (8-bit),
black (0%) - reference white (100%) ,
-7% to 109% total valid range (used in Ramps,
High-GS mode, etc.)
Cb,Cr 64-960 (10-bit) or 16-240 (8-bit)
** R,G,B 0-1023 (10-bit) or 0-255 (8-bit),
black (0%) - reference white (100%)
Sync Selection
Pos, Neg, Zero
–
Used with Generator Sync/Position sub-
menu item to increment, decrement, and reset (zero) the
Hsync and Vsync positions.
Note: HV sync polarity for digital signals is set according to the
CTA-861-F standard. But the digital HV sync polarity can be
overridden in the Generator Output 2 sub-menu.