DGA-6000 ULTRA-HD VIDEO GENERATOR / ANALYZER USER MANUAL
28
Gray Scale Groups
-
10-Step Vertical Gray Scale Linearity (3)
- Check grayscale tracking and color temperature. 0%-
100% in 10% steps, Low-GS 0%-10% in 1% steps, High-GS 100%-109% in 0.9% steps.
-
10-Step Split Vertical Gray Scale Linearity (3)
- Check grayscale tracking and color temperature.
0%-100% in 10% steps, Low-GS 0%-10% in 1% steps, High-GS 100%-109% in 0.9% steps.
-
10-Step Horizontal Gray Scale Linearity (3)
- Check grayscale tracking and color temperature. 0%-
100% in 10% steps, Low-GS 0%-10% in 1% steps, High-GS 100%-109% in 0.9% steps.
-
GS User, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100% (10)
Low-GS User, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10% (10)
High-GS User, 100.9, 101.8, 102.7, 103.6, 104.5, 105.4, 106.3, 107.2, 108.1, 109.0% Windows
w/PLUGE
- Calibrate color temperature, grayscale, and gamma. PLUGE bars ensure black level
doesn’t shift while adjusting grayscale tracking. The border surrounding the High-GS windows is
100% luma to examine a display’s ability to differentiate levels near 100%. The borders surrounding
all the Gray Scale Windows can be changed with the User Win Border OSD menu item or with USB
commands. Window sizes may be selected from 5.0% to 20.0%. PLUGE stripes may be turned on or
off.
Gray Field Group
-
100%, 0% Gray Field (2) -
Measure full-field (on-off, 0%/100%) contrast ratio.
-
25%, 50%, 75% Gray Fields (3) -
Measure flat field uniformity.
-
User Luma Level Field
– Enter luma value in OSD User menu.
-
10, 20, 30, 40, 50, 60, 70, 80, 90% Gray Fields (9)
- Measure flat field uniformity, and calibrate
gamma and grayscale tracking with full-field output levels
.
Gray2Color Pattern Feature
Converts all non-color (gray) patterns in the Special, PLUGE, Gray Scale, and Gray Field pattern
groups to a selected color – Off (gray), Green, Blue, Red, Cyan, Yellow, or Magenta. The
Gray2Color feature is also available for 3D patterns and the Pro Motion Option patterns. Not
available for YCbCr 4:2:0 formats.