REPLACEMENT PARTS AND SERVICE
Over Firing Of Burner
Never "over fire" adjusting gas pressure or drilling out the orifice to increase Btu/hr above nameplate specifications. Over firing
can cause permanent damage to firebox and deterioration of parts and void warranty.
Maintaining Correct Pilot-Flame
The pilot flame must be checked during initial installation and annually by a qualified technician. This fireplace uses flame
rectification technology. If the pilot flame is turned down too low, the flame sensor may not detect the pilot flame and the
pilot may not stay lit. Do not turn down the pilot flame. The flame sensor rod may be coated with debris after a few months of
use. It is important to clean the flame sensor rod using emery cloth if flame rectification problems are encountered after use
for a few months. Environmental factors beyond the control of Acadia can cause flame rectification concerns.
How To Access Components
The descriptions below show where the main components are located and how to access them for service. The descriptions
show how to access the components after the installation. All components are also accessible from the outside of the fireplace
before the it is installed.
Pilot:
The pilot is in the back left corner of the firebox behind the burner.
Gas Valve:
The main gas valve is located in the bottom cavity of the firebox.
Complete Valve Assembly:
To make working on components easier, this fireplace has been designed with the valve, pilot,
shutter boxes, shutter cables and gas lines as part of one assemble that can be removed.
Ignition Control Module:
The ignition control module is mounted in the lower cavity in front of the gas valve. The ignition control
module is installed in a box on the floor with an ON/OFF switch.
Convection Blower:
The convection blower is mounted on the firebox’s rear wall behind the control module.
Accent Light:
The accent light is mounted in the firebox top center area.
Part No.
Description
Qty.
28337
Burner Shelf
1
28338
Left Liner Tab
2
28339
Right Liner Tab
2
28909
Pass Through Cover
1
610633 Burner Sub Assembly
1
80775
High Temp Light Assembly
1
80766
G9 Base Bulb
1
610693 Co-Linear Air Duct
1
88297
Co-Linear Air Slide Gasket
1
88305
Burner Plate Side Gasket
2
88306
Burner Plate Front And Rear Gasket
2
88307
Light Gasket
1
88309
Pass Through Gasket
2
610685 Glass Door Frame Assembly
1
80709
Blower
1
610768 Control Module Box Assembly
1
28786
Electrical Box Lid
1
80763
IFC Wire Harness, No CPI Switch
1
80772
IFC On/Off Switch Harness, 4”
1
80649
Ground Wire
1
80773
IFC Fan/Light Harness, 11.50”
1
C42373 Rocker Switch
1
28785
Electrical Box
1
610789 Burner Plate Assembly
1
81297
Gas Pilot
1
893032 On/Off Ball Valve
1
610797 Log Retainer Assembly
1
80761
9V Battery Box
1
892978 Inlet Tube Assembly
1
80762
Sit Transmitter (Remote) (Sit #0.584.040)
1
INSTALLATION