p-40-ed-3-en
11.8
05-10-25
748
(NHOS/NPW/EST/RIV/RIUNT/NAPO) Input E3 is
B,C
0001 - 0007 5
Kl. 1, 2, 3, 4
1 = needle up without trimming
2 = needle position change-over
3 = single stitch
4 = single stitch with reduced length
5 = backtack inversion
6 = backtack suppression
7 = change-over position
8 = puller lift switched off
757
(TUM) Feed reverse speed of reaction (40, 50,
B,C
0000 - 0255 25
Kl. 2
60 ms)
-
Kl. 1, 3, 4
760
(FW/SPFW/STZ/STZA)
A,B,C
0000 - 0250 5
Kl. 1, 2, 3, 4
- Stitch count for the remnant thread after the
bobbin thread monitor responds with direct bobbin
thread monitoring
- Multiplicator for the fixed value (200) for
determining the start value of the stitch counter
with indirect bobbin thread monitoring
761
(FSL/FZ/VERZ) Prolongation Thread tension release/ B,C
0000 - 0080 0
Kl. 1, 2, 3, 4
Thread puller
762
Kein Kommentar vorhanden
B,C
0000 - 0255 196
Kl. 4
-
Kl. 1, 2, 3
763
Kein Kommentar vorhanden
B,C
0000 - 0255 1
Kl. 4
-
Kl. 1, 2, 3
770
(PF/VERZ) Lifting delay of presser foot at threadle-
B,C
0010 - 0250 80
Kl. 1, 2, 3, 4
position „-1“
775
(ZRIE/STOPZ) Stop time (ms) with stitch in stitch
B,C
0010 - 1000 100
Kl. 1, 3, 4
backtack (decorative backtack)
0010 - 1000 150
Kl. 2
789
(PEIPO) Needle position 10
B,C
0000 - 0255 248
Kl. 1, 2, 3, 4
(target stitch)
797
(HWT) Hardware test
C
0
Kl. 1, 2, 3, 4
1 yes
0 no
798
(EBC) Programming level C
A,B,C
0000 - 0020 1
Kl. 1, 2, 3, 4
1 yes
0 no
799
(MAKL) Machine class which has been selected
C
0001 - 0004 1
Kl. 1 *
0001 - 0004 2
Kl. 2
0001 - 0004 3
Kl. 3
0001 - 0004 4
Kl. 4
800
(DRR) Direction of motor rotation viewed from belt
C
0000 - 0001 0
Kl. 1 *
pulley
0000 - 0001 1
Kl. 2, 3, 4
1 left-hand rotation
0 right-hand rotation
801
(RDR) Reverse rotation angle after seam end
B,C
0010 - 0212 32
Kl. 1, 2, 3, 4
880
(REG) Starting current max. [A]
C
0001 - 0010 5
Kl. 1, 2, 3
0001 - 0010 8
Kl. 4
884
(REG) Proportional amplification of the speed control B,C
0003 - 0024 9
Kl. 1
(in general)
0003 - 0030 16
Kl. 2
0003 - 0024 10
Kl. 3
0003 - 0024 6
Kl. 4
885
(REG) Integral amplification of the speed control
C
0010 - 0080 50
Kl. 1, 2, 3
0010 - 0080 23
Kl. 4
886
(REG) Proportional amplification of the order
C
0001 - 0015 8
Kl. 1, 2, 3, 4
controllers
887
(REG) Differential amplification of the order
C
0001 - 0015 8
Kl. 1, 2, 3, 4
controllers
889
(EINZ/REG) Time required for order controlling
C
0000 - 2500 200
Kl. 1, 2, 3, 4
(0 = always)
890
(REG) Proportional amplification of the superior
C
0001 - 0025 15
Kl. 1, 2, 3
order controllers for the residual brake
0001 - 0025 22
Kl. 4
897
(MOT) MINI motor version
C
0000 - 0001 0
Kl. 1, 3, 4 *
1 long
0000 - 0001 1
Kl. 2
0 short