Installation –
Requirements for the installation site |
13
Installation
When installing the POLEMH6, various specifications regarding the location and the connection technology must be
met in order to ensure safe operation.
Requirements for the installation site
The POLEMH6 was developed for outdoor use. To ensure proper installation, you as the operator must adhere to the
following specifications regarding the location and positioning.
Be sure to observe all local regulations for electrical installations, fire prevention and accident prevention.
All guidelines for the installation of low-voltage systems in accordance with IEC 60364-1 and IEC 60364-5-52
apply.
The installation surface must have sufficient strength to withstand the mechanical loads. It is therefore strongly
recommended not to install the POLEMH6 directly on asphalt or a concrete floor, but to use a concrete foundation
such as the ABL EMH9996 with suitable specifications (concrete C20/25 in accordance with EN 206-1:2013).
A sufficiently dimensioned supply cable for the power supply of the respective wallbox must be provided at
the installation location. The supply cable must be laid so that it lines up with the pipe opening in the concrete
foundation and in the ground. If necessary, the supply cable must be protected against mechanical influences (by
a suitable hose or pipe) in the area in front of the foundation.
To integrate the wallbox(es) installed on the POLEMH6 in a group installation, suitable data cables must also be
laid to the installation location.
Suitable collision protection must be provided on site to provide the POLEMH6 with mechanical protection from
collision with a vehicle.
The minimum distance between the vehicle and the POLEMH6 should be no less than 50 cm and no more than
150 cm.
Select the installation location so that the charging cable from the wallbox easily reaches the charging socket on
the vehicle: the cable must not under any circumstances be strained when connected to the vehicle.
For the safe operation of your mounting pole, minimum distances to other technical installations must be ob-
served: you can obtain further information from your electrical contractor or distributor.
The POLEMH6 should not be installed in high-traffic areas or along thoroughfares.
The POLEMH6 is designed for operation at high ambient temperatures. However, it is important to ensure that the
maximum permissible operating temperature is not exceeded due to external influences such as direct sunlight or
similar.
Specifications for the mechanical installation of the POLEMH6
The entire installation of the POLEMH6 should always be carried out by qualified personnel: at least two people are
required for the mechanical installation.
For mechanical installation of the POLEMH6, you will need the following components:
Key for unlocking the housing
cover (included with the
POLEMH6)
EMH9996 concrete foun-
dation for installing the
mounting pole (available as
accessory)
DIN 912 A2 M10×35 hexagon
socket screw, 4 pieces
(included with the EMH9996)