| Dimensional drawings and dimensions –
EMH9996
10
Detailed view of the top side
A
A
B
C
A
These four threaded anchors are used to mount the base of
the POLEMH6 mounting pole using the washers and M10×35
hexagon socket screws supplied.
B
The two empty conduits are used to feed the supply and data
cables through the foundation into the POLEMH6.
C
If the POLEMH6 is installed outside the rolling sphere,
grounding anchors can be attached here with M12 threads.