![Abicor Binzel ABICAR 1200 PRO Operating Instruction Download Page 48](http://html1.mh-extra.com/html/abicor-binzel/abicar-1200-pro/abicar-1200-pro_operating-instruction_3419892048.webp)
EN
-
18
6 Putting into operation
ABICAR 1200 PRO
Setting the oscillation weld parameters (optional)
6.8 Connecting the oscillator auf Seite EN
Once the optional oscillator has been connected, the oscillation parameters can be set in the configuration
menu. The following figure shows a graphic representation of the weld oscillation parameters.
6.6 Mounting the welding torch
Continual contact must be ensured between the device and the workpiece. Adjustment can be made either
by means of the guide arms or the corresponding accessories.
6.1 Adjusting and changing guide arms auf Seite EN
Fig. 11
Weld oscillation parameters
Tab. 6
Overview of weld oscillation parameters
Parameter
Value
Description
Osc. Amplitude
0–100 %
Relative oscillation width
Osc. Speed
0–100 %
Relative oscillation speed.
The higher the speed, the shorter the
oscillation duration.
Osc. Delay 1
0.0–5.0 s
Time delay in the upper oscillation position
Osc. Delay 2
0.0–5.0 s
Time delay in the lower oscillation position
Osc. Hold-time lock
YES
NO
YES = Time delay cannot be changed
during welding.
NO: Time delay can be changed during
welding.
Osc. Delay 1
Osc. Speed
Osc. Delay 2
Weld seam length
Start point
Endpoint
Osc. Amplitude