2 Installation
2.7.2. Installation of Spotwelding Cabinet
3HAC027309-001 Revision: D
134
©
Co
py
rig
h
t 200
6-
201
0 ABB. All righ
ts reser
v
ed.
Connection
The following procedures details how to connect the power and signals to the spotwelding
cabinet.
For connections in IRC5 controller, see
Installation of add-ons, Product manual IRC5.
Action
Note
1. Drill a hole for cable gland in one of the
covers on the rear plate.
NOTE!
Locknut maximum width Ø60mm.
xx0500002521
2. Fit the cable gland.
3. Connect the incoming power.
NOTE!
Max wire range:
•
3 x 70 mm
2
T1
•
3 x 95 mm
2
T2
•
3 x 185 mm
2
T3
xx0500002522
•
A: Incoming power
•
B: Outgoing power
Continued