SCT
System configuration tool according to standard IEC 61850
SDU
Service data unit
SMA connector
Subminiature version A, A threaded connector with constant
impedance.
SMT
Signal matrix tool within PCM600
SMS
Station monitoring system
SNTP
Simple network time protocol – is used to synchronize computer clocks
on local area networks. This reduces the requirement to have accurate
hardware clocks in every embedded system in a network. Each
embedded node can instead synchronize with a remote clock,
providing the required accuracy.
SOF
Status of fault
SPA
Strömberg protection acquisition, a serial master/slave protocol for
point-to-point communication
SRY
Switch for CB ready condition
ST
Switch or push button to trip
Starpoint
Neutral point of transformer or generator
SVC
Static VAr compensation
TC
Trip coil
TCS
Trip circuit supervision
TCP
Transmission control protocol. The most common transport layer
protocol used on Ethernet and the Internet.
TCP/IP
Transmission control protocol over Internet Protocol. The de facto
standard Ethernet protocols incorporated into 4.2BSD Unix. TCP/IP
was developed by DARPA for Internet working and encompasses both
network layer and transport layer protocols. While TCP and IP specify
two protocols at specific protocol layers, TCP/IP is often used to refer
to the entire US Department of Defense protocol suite based upon
these, including Telnet, FTP, UDP and RDP.
TEF
Time delayed earth-fault protection function
TLS
Transport Layer Security
TM
Transmit (disturbance data)
TNC connector
Threaded Neill-Concelman, a threaded constant impedance version of a
BNC connector
TP
Trip (recorded fault)
TPZ, TPY, TPX, TPS
Current transformer class according to IEC
TRM
Transformer Module. This module transforms currents and voltages
taken from the process into levels suitable for further signal
processing.
TYP
Type identification
UMT
User management tool
Underreach
A term used to describe how the relay behaves during a fault condition.
For example, a distance relay is underreaching when the impedance
presented to it is greater than the apparent impedance to the fault
applied to the balance point, that is, the set reach. The relay does not
“see” the fault but perhaps it should have seen it. See also Overreach.
1MRK 505 293-UEN B
Section 10
Glossary
Breaker protection REQ650
115
Commissioning manual
© Copyright 2013 ABB. All rights reserved
Summary of Contents for REQ650 1.3 IEC
Page 1: ...Relion 650 SERIES Breaker protection REQ650 Version 1 3 IEC Commissioning manual ...
Page 2: ......
Page 12: ...6 ...
Page 20: ...14 ...
Page 28: ...22 ...
Page 40: ...34 ...
Page 42: ...36 ...
Page 116: ...110 ...
Page 123: ...117 ...