4
Table 2: Location of Wall-Rails: Meter Modules
*Underscores in the catalog indicate characters that are variable which don’t impact the dimensions in the table
Catalog Number
Dimensions (inches)
Height
Width
Depth
V1
X1
Y
Z
Residential 125A Socket
RMS_212H_
45 3/16
13 7/8
9 1/2
12 1/16
33 1/8
6 3/4
2 1/4
RMS_312H_
45 3/16
13 7/8
9 1/2
12 1/16
33 1/8
15 3/4
2 1/4
RMS_412H_
54 3/16
13 7/8
9 1/2
21 1/16
33 1/8
15 3/4
11 1/4
RMS_512H_
63 3/16
13 7/8
9 1/2
21 1/16
42 1/8
24 3/4
11 1/4
RMS_612H_
72 3/16
13 7/8
9 1/2
30 1/16
42 1/8
24 3/4
20 1/4
RMS_212L_
46 7/16
13 9/16
8 15/16
15 1/16
31 3/8
6 3/4
2 1/4
RMS_312L_
46 7/16
13 9/16
8 15/16
15 1/16
31 3/8
15 3/4
2 1/4
RMS_412L_
55 7/16
13 9/16
8 15/16
24 1/16
31 3/8
15 3/4
11 1/4
RMS_512L_
64 7/16
13 9/16
8 15/16
24 1/16
40 3/8
24 3/4
11 1/4
RMS_612L_
73 7/16
13 9/16
8 15/16
33 1/16
40 3/8
24 3/4
20 1/4
Residential 225A Socket
RMS_222H_
57 15/16
18 3/8
9 5/8
23 5/16
34 5/8
3 7/16
8 9/16
RMS_322H_
57 15/16
18 3/8
9 5/8
23 5/16
34 5/8
15 7/16
8 9/16
RMS_422H_
69 15/16
18 3/8
9 5/8
23 5/16
46 5/8
27 7/16
8 9/16
RMS_522H_
81 15/16
18 3/8
9 5/8
35 5/16
46 5/8
27 7/16
20 9/16
RMS_222L_
59 7/8
18 3/8
9 5/8
23 5/16
36 9/16
3 7/16
8 9/16
RMS_322L_
59 7/8
18 3/8
9 5/8
23 5/16
36 9/16
15 7/16
8 9/16
RMS_422L_
71 7/8
18 3/8
9 5/8
23 5/16
48 9/16
27 7/16
8 9/16
RMS_522L_
83 7/8
18 3/8
9 5/8
35 5/16
48 9/16
27 7/16
20 9/16
Commercial Lever Bypass (LVBP)
225A and 400 Socket
RMS_12122CHLBR
54 1/16
19 5/8
9 11/16
24 1/2
29 9/16
n/a
4 11/16
RMS_12222CHLBR
54 1/16
19 5/8
9 11/16
24 1/2
29 9/16
9 5/16
4 11/16
RMS_12322CHLBR
68 1/16
19 5/8
9 11/16
24 1/2
43 9/16
23 5/16
4 11/16
RMS_12422CHLBR
82 1/16
19 5/8
9 11/16
38 1/2
43 9/16
23 5/16
18 11/16
RMS_12140CHLBRB
42 1/4
23 5/16
10 13/16
14 11/16
27 5/8
5 5/8
n/a
RMS_12240CHLBRB
70 1/4
23 5/16
10 13/16
25 3/16
45 1/8
23 1/8
4 7/8
RMS312140CHLBR
54 3/4
20 1/16
10 13/16
24 7/8
29 7/8
n/a
4 3/8
Before mounting the unit, rotate the swivel bracket in the back
of the product outwards so they can be accessible. Mount the
unit on to the wall rail. Assure the enclosure rail catches on to
the wall rail.
Complete the fastening of the units to the wall by using
the swivel wall brackets.Rotate the swivel wall brackets to
the position desired. Use appropriate hardware to fasten
to your wall.
Caution:
Avoid over-rotation of the swivel wall bracket, as it
may become loose.
Subsequent wall rails can be placed simply by aligning with the
wall rail of unit beside it already mounted. For main-modules,
the end-caps on each side of the module need to be removed
before units can be ganged together. Mount and fasten as
described in step 2.
2. Mount and fasten the unit to the wall
3. Subsequent units
Warning:
Heavy equipment greater than 50 lbs. Can cause serious
injury. Use appropriate protective equipment, and follow
safety regulations to handle and mount the equipment.