Se pueden utilizar los sigientes pernos de compresión que estan aprobados por UL

Tamaño del cable

ABB/ T&B

Burndy

Panduit

MAC

CU only

CU/ AL

CU only

CU/ AL

CU only

CU/ AL

CU only

CU/ AL

250 MCM

54275

60256

YA29-2LN

YA29A3

LCC250-12

LAB250-12

MSB250-8N

MLB250-8N

54868BE

YA29-2N

YA29AY-2N

MRB250-8N MULB250-8N

300 MCM

54280

60262

YA30-2LN

YA30A3

LCC300-12

LAB300-12

MSB300-8N

MLB300-8N

54870BE

YA30-2N

YA30AY-2N

MRB300-8N MULB300-8N

350 MCM

54282

60267

YA31-2LN

YA31A3

LCC350-12

LAB350-12

MSB350-8N

MLB350-8N

54872BE

YA31-2N

YA31AY-2N

MRB350-8N MULB350-8N

400 MCM

54874

60269

YA32-2LN

YA32A3

LCC400-12

LAB400-12

MSB400-8N

MLB400-8N

YA32-2N

YA32AY-2N

MRB400-8N MULB400-8N

500 MCM

54266

60273

YA34-2LN

YA34A3

LCC500-12

LAB500-12

MSB500-8N

MLB500-8N

54876BE

YA34-2N

YA34AY-2N

MRB500-8N MULB500-8N

600 MCM

54289

60275

YA36-2LN

YA36A3

LAB600-12

MSB600-8N

MLB600-8N

54878BE

YA36-2N

YA36AY-2N

MRB600-8N MULB600-8N

700 MCM

54291

60277

750 MCM

54223

YA39-2LN

LCC750-12

LAB750-12

MSB750-8N

54880BE

YA39-2N

MRB750-8N

Enlace neutro en módulos principales

El neutro no viene conectado de fábrica a la caja.Si necesita 

conectar el neutro, utilice el puente de conexión suministrado 

con la unidad.  Desabrochar desde la posición de instalación en 

fábrica Gire el puente y fíjelo al bus neutro al par indicado en la 
etiqueta de la unidad. Fije el puente a la caja con la tornillería 

suministrada al par indicado en la etiqueta de la unidad.

Accesorios para disyuntores

Los siguientes accesorios del disyuntor pueden instalarse in situ.
Se venden por separado.

Shunt-trip

Provisión de candado en el interruptor principal

Número de 
catálogo

Aplicación

Sistema eléctrico

Calificación principal

RXT7LUGKIT750

120/240V or 
208Y/120V

Para uso con cualquier 
módulo principal con 

dispositivo XT7 Frame 1000A 
y 1200A MCB's y 800A MFS.  

Este kit de terminales 
permite la instalación in situ 
de terminales más grandes 

que admiten (3) cables AL/
CU de 500-750 kcmil por fase 

y neutro.

Número de 
catálogo

Aplicación

Sistema eléctrico

Clasificación del 
interruptor principal

1SDA104934R1

120/240V

400A, 600A, 800A

1SDA073672R1

110/120V

1000A, 1200A

1SDA073674R1

220/240V

1000A, 1200A

1SDA038290R1

110/120V

1400A, 1600A, 2000A

1SDA038292R1

220/240V

1400A, 1600A, 2000A

Número de 
catálogo

Aplicación

Interruptor principal

Interruptor principal

1SDA105099R1

400A, 600A

400A

1SDA105102R1

800A

600A

1SDA105104R1

1000A, 1200A

800A

1SDA038351R1

1400A-1600A-2000A

n/a

Para los módulos principales con preinstalación para terminales 
de compresión de línea, utilice los siguientes terminales de 
compresión:

Lug-kit

Summary of Contents for ReliaMod RMM B 4R

Page 1: ...ones en espa ol v ase la p gina 16 HAZARDOUS VOLTAGE WILL CAUSE SEVERE INJURY OR DEATH Turn OFF power supplying this equipment before working inside Please read these instructions completely before in...

Page 2: ...Mounting of units Meter module Electrical code or project spec Electrical code or project spec Grade level Utility spec Min meter position Utility spec Max meter position Main module V2 V1 X2 X1 A Y Z...

Page 3: ...52 5 8 RMM_BB20R 60 5 8 38 5 16 24 3 16 8 52 5 8 Main Lug Module RMM_L4R 48 13 3 4 6 1 2 15 15 16 32 1 16 RMM_L6R 47 15 16 16 3 4 6 1 2 14 5 16 33 5 8 RMM_L8R 47 15 16 20 5 16 11 1 4 12 7 8 35 1 16 RM...

Page 4: ...7 8 18 3 8 9 5 8 35 5 16 48 9 16 27 7 16 20 9 16 Commercial Lever Bypass LVBP 225A and 400 Socket RMS_12122CHLBR 54 1 16 19 5 8 9 11 16 24 1 2 29 9 16 n a 4 11 16 RMS_12222CHLBR 54 1 16 19 5 8 9 11 16...

Page 5: ...ttom end walls on main modules can be removed from the enclosure to ease the punching of holes for bot tom fed conduit and conductors the mounting screws to maintain NEMA 3R enclosure rating The embos...

Page 6: ...need to bond the neutral use the bonding jumper supplied with the unit Unfasten from the factory installed position Rotate jumper and fasten to the neutral bus at torque indicated on label in unit Se...

Page 7: ...Trip Unit Default PIN is 00001 The following is a step by step guide for implementing RELT settings and ensuring proper operation of the RELT function for XT7 touch trip units Enter the submenu for th...

Page 8: ...ct Protection Press Enter Scroll down to ON Press Enter arrow pushbutton Scroll down to Threshold MM Press Enter arrow pushbutton Adjust the threshold using UP and Down Arrows pushbuttons Press Enter...

Page 9: ...f Complete the fastening of the breaker to its mounting plate by torquing the mounting screws to 10 in lbf THQL THHQL are plug in type breakers All other breakers are bolt on Installation of A1 breake...

Page 10: ...ker Installation of XT3 Breakers Mount breaker on its plate with the straps aligned with busbars on the meter module Use the mounting screws included in the breaker package to fasten the breaker to th...

Page 11: ...s 1 Gang 2 Gang 3 Gang 4 Gang 5 Gang 6 Gang 1 meter at the top A C A C A C A C A C A C 2 A B A B A B A B A B 3 B C B C B C B C 4 A C A C A C A C 5 A B A B 6 B C Position A C Position A B Position B C...

Page 12: ...ion B C to position A B 4 Install strap in position C 5 Tighten all connections to 170 in lbf Conversion from A C to A B 2 Remove meter barrier at location to convert 3 Remove C phase strap 4 Install...

Page 13: ...and insulation sheet 6 Tighten all connections to 170 in lbf 7 Re install meter barrier Conversion from B C to A B 2 Remove meter barrier at location to convert 3 Remove C phase strap 4 Switch phase...

Page 14: ...meter jaws and disactivate the bypass 6 Replace the ringless meter cover NOTE Meter cover cannot be installed with the lever in the bypass mode Warning Hazardous Voltage can cause serious injury or d...

Page 15: ...h the meter module Remove inch knockout and install sealing screw provided Install utility seal through the hole in the sealing screw and the slot in the hasp Provision for utility seal Provision for...

Page 16: ...de este equipo antes de realizar cualquier trabajo dentro o fuera de l Lea atentamente estas instrucciones antes de instalar o retirar el dispositivo Una instalaci n incorrecta podr a resultar peligro...

Page 17: ...o o especificaci n del proyecto C digo el ctrico o especificaci n del proyecto Nivel de grado Requisito de la empresa de servicio publico Posici n min del medidor Requisito de la empresa de servicio p...

Page 18: ...5 8 38 5 16 24 3 16 8 52 5 8 Modulo principal con zapatas RMM_L4R 48 13 3 4 6 1 2 15 15 16 32 1 16 RMM_L6R 47 15 16 16 3 4 6 1 2 14 5 16 33 5 8 RMM_L8R 47 15 16 20 5 16 11 1 4 12 7 8 35 1 16 RMM_L12R...

Page 19: ...comercial LVBP de 225A y toma de 400A RMS_12122CHLBR 54 1 16 19 5 8 9 11 16 24 1 2 29 9 16 n a 4 11 16 RMS_12222CHLBR 54 1 16 19 5 8 9 11 16 24 1 2 29 9 16 9 5 16 4 11 16 RMS_12322CHLBR 68 1 16 19 5 8...

Page 20: ...venden por separado Conductores de L nea alimentados por el fondo Las paredes inferiores de los m dulos principales pueden retirarse de la caja para facilitar la perforaci n de orificios para conducto...

Page 21: ...nidad Desabrochar desde la posici n de instalaci n en f brica Gire el puente y f jelo al bus neutro al par indicado en la etiqueta de la unidad Fije el puente a la caja con la torniller a suministrada...

Page 22: ...PIN predeterminado es 00001 La siguiente es una gu a paso a paso para implementar los ajustes RELT y garantizar el correcto funcionamiento de la funci n RELT para las unidades de disparo por contacto...

Page 23: ...eleccione Protecci n Pulse Intro Despl cese hasta ON Pulse el bot n de flecha Intro Despl cese hasta Umbral MM Pulse el bot n de flecha Intro Ajuste el umbral con los pulsadores de flecha ARRIBA y ABA...

Page 24: ...la fijaci n del interruptor a su placa de montaje apretando los tornillos de montaje a 10 in lbf THQL THHQL son interruptores autom ticos enchufables Todos los dem s disyuntores son atornillables Ins...

Page 25: ...vez instalados los conductores Formula A2 marco disyuntores XT4 marco disyuntores XT3 marco disyuntores Instalaci n de disyuntores XT3 Monte el disyuntor en su placa con las correas alineadas con las...

Page 26: ...iento Phase Link 3 8 Herrajes 1 Desconecte la alimentaci n del equipo Conversi n de A C a B C 2 Retire la correa en la posici n A 3 Instale el enlace de fase el aislamiento y el perno 3 8 en la posici...

Page 27: ...as las conexiones a 170 in lbf Conversi n de A C a A B 2 Quitar la barrera del contador en el lugar a convertir 3 Quitar la correa de la fase C 4 Instale el enlace de fase el aislamiento y el perno 3...

Page 28: ...te todas las conexiones a 170 in lbf 7 Volver a instalar la barrera de contadores Conversi n de B C a A B 2 Quitar la barrera del contador en el lugar a convertir 3 Quitar la correa de la fase C 4 Int...

Page 29: ...mand bula a la derecha Funci n de derivaci n de la palanca Instalaci n o sustituci n delcontador en un m dulo contador de derivaci n de palanca PRECAUCI N Debe ser realizado por personal de servicio a...

Page 30: ...lado suministrado con el m dulo contador Retire el orificio ciego de de pulgada e instale el tornillo de sellado suministrado Instale la junta de estanqueidad a trav s del orificio del tornillo de est...

Reviews: