3 Maintenance
3.7.6. Exporting the SIS data
243
3HAC022033-001 Revision: K
©
Co
py
rig
h
t 200
4-
201
1 AB
B. All
ri
gh
ts reser
v
ed.
3.7.6. Exporting the SIS data
General
This section describes the available variables for entering SIS parameters as well as showing
any values of exceeded time limits as detected by the SIS counters.
In a M2000 robot system, the values can be read on a PC using "Webware SDK". How to
access these variables and how to perform the actual programming sequences are detailed in
the robot system User's Guide.
Definitions
The table below defines the names and functions of all software variables available for
communication between the SIS and an external computer.
Signal
Unit
Counter type
Function
sisRestartDate
sec
Calendar time
The date on which the supervision was
started/reset last time.
sisCalendarT
sec
Calendar time
The number of hours since start/last reset.
sisTotRunT
sec
Operation time
Total number of operation hours since the
system was started. Corresponds to the
operating time counter on the control cabinet.
sisRunT
sec
Operation time
The number of operation hours since start/
last reset of the operation time counter.
Corresponds to the operating time counter on
the control cabinet.
sisL10h_1
hrs
Gearbox time
Estimated life of gearbox axis 1
sisL10h_Time_1
sec
Gearbox time
Operation time of gearbox axis 1
sisL10h_2
hrs
Gearbox time
Estimated life of gearbox axis 2
sisL10h_Time_2
sec
Gearbox time
Operation time of gearbox axis 2
sisL10h_3
hrs
Gearbox time
Estimated life of gearbox axis 3
sisL10h_Time_3
sec
Gearbox time
Operation time of gearbox axis 3
sisL10h_6
hrs
Gearbox time
Estimated life of gearbox axis 6
sisL10h_Time_6
hrs
Gearbox time
Operation time of gearbox axis 6