4 Repair
4.3.1. Replacement of cable harness, axes 1-4
3HAC022033-001 Revision: K
256
©
Co
py
rig
h
t 200
4-
201
1 AB
B. All
ri
gh
ts reser
v
ed.
3. Pull the cable and connectors down through the
cable guide in the center of the frame.
Make sure the cables are not
twisted with each other or with
eventual customer harnesses!
Make a note of the correct positions
of the connectors!
4. Reconnect connectors
R1.MP and R1.SMB
at the
rear cover plate.
Make a note of the correct positions
of the connectors!
Attachment point is shown in the
figure
5. Reconnect the earth cable.
Attachment point is shown in the
figure
6. Refit the
rear cover plate
to the robot with its
attachment screws.
.
7. Reconnect all connectors at motors 1 and 2.
Specified and shown in the figure
Location of cable harness on page
251
!
Action
Note
Continued
Continues on next page