2 Installation and commissioning
2.6.2. Mechanically restricting the working range of axis 1
115
3HAC022033-001 Revision: K
©
Co
py
rig
h
t 200
4-
201
1 AB
B. All
ri
gh
ts reser
v
ed.
2.6.2. Mechanically restricting the working range of axis 1
General
The working range of axis 1 is limited by fixed mechanical stops and adjustment of the
system parameter configuration. The working range can be reduced by adding additional
mechanical stops giving 7.5 or 15 graduation, between 22.5° and 135° in both directions.
Mechanical stops, axis 1
The illustration shows the mounting position of the stop pin and one of the additional
mechanical stops available for axis 1.
xx0300000049
Required equipment
A
Additional mechanical stop
B
Stop pin
Equipment, etc.
Art. no.
Note
Mechanical stop for axis 1, 7.5°
3HAC11076-1
Includes attachment screws
and an assembly drawing.
Mechanical stop for axis 1, 15°
3HAC11076-2
Includes attachment screws
and an assembly drawing.
Standard toolkit
-
Content is defined in section
.
User’s guide - S4Cplus (RobotWare
4.0)
Technical reference manual - System
parameters
-
Art. no. is specified in section
Continues on next page