![ABB IRB 7600 Series Product Manual Download Page 412](http://html.mh-extra.com/html/abb/irb-7600-series/irb-7600-series_product-manual_5083412.webp)
5 Calibration information
5.5. Updating revolution counters
3HAC022033-001 Revision: K
410
©
Co
py
rig
h
t 200
4-
201
1 AB
B. All
ri
gh
ts reser
v
ed.
Step 2 - Storing the revolution counter setting with the FlexPendant
Use this procedure to store the revolution counter setting with the FlexPendant (IRC5).
8.
CAUTION!
If a revolution counter is incorrectly updated, it will cause incorrect robot
positioning, which in turn may cause damage or injury!
Check the calibration position very carefully after each update.
How to perform the check is detailed in section
Action
Note
Action
1. On the
ABB
menu, tap
Calibration
.
All mechanical units connected to the system are shown with their calibration status.
2. Tap the mechanical unit in question.
A screen is displayed, tap
Rev. Counters
.
en0400000771
3. Tap
Update Revolution Counters...
.
A dialog box is displayed warning that updating the revolution counters may change
programmed robot positions:
•
Tap
Yes
to update the revolution counters.
•
Tap
No
to cancel updating the revolution counters.
Tapping
Yes
displays the axis selection window.
4. Select the axis to have its revolution counter updated by:
•
Ticking in the box to the left
•
Tapping
Select all
to update all axes.
Then tap
Update
.
Continued
Continues on next page
工控帮助教小舒QQ2823408167