Periodic check of the calibration tool
If including the calibration tool in a local periodic check system, the following
measures should be checked.
•
Outer diameter within Ø12g4 mm, Ø8g4 mm or Ø6g5 mm (depending on
calibration tool size).
•
Straightness within 0.005 mm.
xx1500000951
Outer diameter
A
368
Product manual - IRB 4600 Foundry Prime
3HAC040585-001 Revision: M
© Copyright 2013-2018 ABB. All rights reserved.
5 Calibration
5.4.2 Calibration tools for Axis Calibration
Continued