![ABB IRB 360 Product Manual Download Page 162](http://html.mh-extra.com/html/abb/irb-360/irb-360_product-manual_5042162.webp)
Removal
Note
Action
If necessary, change them.
Remove the
flange screws
and
washers
and check
them.
1
CAUTION
The base cover has sharp edges,
use protective gloves.
Remove the
base cover
.
2
See article number in
Product
manual, spare parts - IRB 360
.
Remove and discard the
hollow o-ring
.
3
See article number in
Product
manual, spare parts - IRB 360
.
Remove and discard the
rubber gaskets
.
4
Refitting
Note
Action
Refit new
rubber gaskets
.
1
Note
Do not lubricate the hollow o-ring
for the base cover, it can slip out
of position when cleaning.
Refit a new
hollow o-ring
.
2
CAUTION
The base cover has sharp edges,
use protective gloves.
Refit the
base cover
.
3
See tightening sequence
and tightening sequence on
page 161
.
Refit the
flange screws
with
plastic washers
.
Note
Check that the washers are not damaged. Replace
if needed.
4
Use
tightening torque 4 Nm
for
both rounds.
Note
Always tighten the base cover screws in two rounds.
162
Product manual - IRB 360
3HAC030005-001 Revision: Z
© Copyright 2008-2021 ABB. All rights reserved.
4 Repair
4.3.1 Replacement of base cover gasket