Removing the axis-5 timing belt
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
Loosening timing belts will release axes. This
means the axes can fall down.
Make sure axes are well supported before
loosening timing belts.
2
xx2200000042
Loosen the screws and move the motor slightly
to slacken the timing belt.
3
xx2200000043
Remove the timing belt from its groove on the
motor.
4
Removing the axis-5 motor
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
Removing motors will release axes. This means
the axes can fall down.
Make sure axes are well supported before remov-
ing motors.
2
Continues on next page
194
Product manual - IRB 1010
3HAC081964-001 Revision: B
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.4.3 Replacing the axis 3-4 assembly unit
Continued