Concluded refitting of the front shaft
Note
Action
Remove the lifting accessory from the bal-
ancing device.
1
xx1200001283
Refit the cable bracket (if not already refit-
ted).
2
xx1200001116
Remove the locking screw (M16x120).
3
Jog axis-2 to:
•
-20° or +20°.
4
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
5
Remove the distance tool.
6
Refit the cover plate.
7
366
3HAC044266-001 Revision: -
© Copyright 2013 ABB. All rights reserved.
4 Repair
4.6.2 Replacing the balancing device
Continued